Striale 86379 Manual Del Usuario página 16

Ocultar thumbs Ver también para 86379:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
4. The WEIGHT will flash and you can press UP or DOWN keys to set your WEIGHT. Press ENTER key to
confirm your WEIGHT. The default WEIGHT is 70kgs or 155lbs.
5. The GENDER will flash and you can press UP or DOWN keys to select your sex. Number 1 means man and
number 0 means female. Press ENTER key to confirm your Gender. The default sex is 1 (MAN).
6. The AGE will flash and you can press UP or DOWN keys to set your AGE. Press ENTER key to confirm your
AGE. The default AGE is 35.
7. Press the START/STOP key to begin body fat measurement. If the window show E on the window, please
make sure your hands are attached well on the grips or the chest belt is touch well on your body. Then press
the START/STOP key again to begin body fat measurement.
8. After finished your measurement, the computer will show the values of BMR, BMI and FAT PERCENT on
the LCD display. Furthermore, the computer will show your own exercise profile for your body type.
9. Press START/STOP key to begin exercise.
Operation guide:
1. Sleep Mode: The computer will enter the sleep mode when there is no signal input and no keys be pressed
after 4 minutes. You can press any key to wake up the computer.
2. BMI (Body Mass Index): BMI is a measure of body fat based on height and weight that applies to both adult
men and women.
3. BMR (Basal Metabolic Rate): Your Basal Metabolic Rate (BMR) shows the number of calories your body
needs to operate. This doesn't account for any activity, it's simply the energy needed to sustain a heartbeat,
breathing and normal body temperature. It measures the body at rest, not sleep, at room temperature.
Error Message:
E1 (ERROR 1):
Normal state:
During workout, when the monitor did not get the count signal from the gear motor more than 4
seconds and check under successive 3 times then the LCD will show E1.
Power on state: The gear motor will return to zero automatically, when the signal of motor cannot be detected
for more than 4 seconds then the gear motor's driver will be cut off immediately and show the
E1 on the LCD display. All the other digital and function mark are blank, and the output signals
are cut off also.
E2 (ERROR 2): When the monitor read the memory data, if the I.D. code is not correct or the memory IC damages
then the monitor will show E2 immediately at power on.
E3 (ERROR 3): After 4 seconds by start mode, the computer detects the faulty motor did not leave the zero point
then the LCD bar displays "E3".
Technical data of the current adapter
1. Available for Input: 230V/50Hz or 60Hz Output: 6V AC/0.5A
2. Available for Input: 110V/50Hz or 60Hz Output: 6V AC/0.5A
LCD Workout Graphics
PRESET PROGRAM PROFILES:
PROGRAM 1
MANUAL
PROGRAM 4
ROLLING
PROGRAM 2
STEPS
PROGRAM 5
VALLEY
PROGRAM 3
HILL
PROGRAM 6
FAT BURN

Publicidad

Tabla de contenido
loading

Tabla de contenido