Digital Inputs - BADU EasyFit Eco VS Ficha Técnica

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 65
WG27.50.009-P
WG27.50.010-P
WG27.50.011-P
EN 26
Setting the parameters:
You change to the setup menu by
pressing the "Setup" button for 3
seconds. There the "Info" button can
be used to scroll through the menu.
The first position of the display
shows the current menu item and the
remaining four positions the
parameter to be set.
If the "S" button is pressed within the
menu, all the changed values are
stored and the setup menu exited.
The text "StorE" is shown in the
display.
If you press the "0" button, the setup
menu is exited without the changed
values being stored.
Priming parameters:
The speed is set under the menu
item "n" while the time during the
priming phase is set under the item
"t".
"t oFF" = no priming phase
from oFF, 1 - 10 minutes can be set

Digital Inputs:

External controlling can be activated
or deactivated with the menu item
"E".
"oFF" = deactivated
"dl" = digital inputs (potential-free)
activated
11|2016

Publicidad

Tabla de contenido
loading

Tabla de contenido