3. NAMES OF TERMINALS AND THEIR OPERATIONS
Terminals of Mounting base
a
b c d
e f g h
E+
E- COM NC TP1 TP2 AM1 AM2
4. WIRING MATERIALS AND WIRING METHODS
Do not wire near equipment that is a strong source of noise.
Do not wire in parallel to commercial power supplies or power lines.
Do not use aerial wiring. All of these installation could result in a malfunction.
Power line wiring
For the wiring materials of power input wires, use wires that have a resistance lower than the maximum allowable
resistance found using the formula below.
To simplify the calculation method in this example, the calculation method is described for the condition where the all
detectors are installed farthest from the power supply device (so that the allowable resistance is minimized).
Calculation method for wire length in one
direction from power supply unit to this detector
Maximum allowable resistance
value for wire material R [Ω/km]
Vc: Output voltage of power supply unit [V]
Vs: Minimum operating voltage of this device = 9 V
L : The wire length from this device to power supply unit (km)
i : Current consumption of this device = 0.035 A
Wire examples
SIR10SA wiring examples
a One channel, single-detector example (1b contact)
E+
E-
1
C
T1
Power supply
Sensor
output
input
Security receiver
b One channel, two-sensor example (1b contact)
E+
E-
1
C
T1
Power supply
Sensor
output
input
Security receiver
Terminal symbol/Name
Power supply input
( a :E+, b :E-)
Alarm output
( c :COM, d :NC)
Tamper output
( e :TP1, f :TP2)
Anti-Masking output
( g :AM1, h :AM2)
CAUTION
Vc - Vs
=
1.2 × (2×L) × i
T2
A1 A2
E+
E-
Error
Error
Power supply
input
input
input
T2
A1 A2
E+
E- COM NC
Error
Error
Power supply
Detection
input
input
input
output
A power supply of 9.0 V to 28.0 V DC is input. It has the
polarity.
This is the 1b non-voltage output.
The allowable contact capacity is 30 V DC/0.3 A
(resistor load).
* When power is not supplied,the output opens.
This is the 1b contact component non-voltage output.
The allowable contact capacity is 30 V DC/0.1 A
(resistor load).
This is the 1b non-voltage output.
The allowable contact capacity is 30 V DC/0.3 A
(resistor load).
* When power is not supplied,the output opens.
Wire Table
ø0.50
ø0.65
Single wire (mm)
Single wire (AWG)
24
22
2
Twisted wire (mm
)
0.20
0.40
Resistance (Ω/km)
89
56
*Use a wire material that ranges from AWG24 to AWG16.
COM NC
TP1 TP2
AM1 AM2
Detection
Tamper
Anti-Masking
output
output
output
Detector
TP1 TP2 AM1 AM2
E+
Tamper
Anti-Masking
Power supply
output
output
input
Detector 1
3
Operation
ø0.80
ø0.90
ø1.00
ø1.20
20
19
18
16
0.50
0.75
0.90
1.30
37
29
24
16
E-
COM NC TP1 TP2 AM1 AM2
Detection
Tamper
Anti-Masking
output
output
output
Detector 2