Congratulation on your purchase of the Taylor Panel Mount Thermometer. Your Thermometer
is an example of superior design and craftsmanship. Please read this instruction manual
carefully before use. Keep these instructions handy for future reference.
Technical Specifications
1. Operating range -40 to 300˚F; or -40 to 150˚ C.
2. Resolution 0.1˚F or 0.1˚C throughout range with 4 digits LCD display.
3. Accuracy +/- 1.8˚F (1˚C) between 14˚F and 212˚F; +/- 3.6˚F (2°C) above or below range.
4. Sampling rate 10 seconds.
5. Case temperature operating range 23 to 122˚F (-5 to 50˚C).
6. Battery type AAA 1.5 volt.
7. F or C selector switch on back of front assembly.
8. Water resistant case and back bracket.
Mounting Options
A. Back bracket can be reversed to put mounting holes above or below the main unit and
LCD display. When mounted with back bracket the thermometer unit is water or moisture
resistant with a plastic lens over the LCD, an o-ring gasket around the bracket seal and
sensor and a gasket around the sensor cord where it exits the housing.
B. Front assembly can be mounted as a panel meter without the back bracket by cutting a
hole in the customers "A" Panel or equipment. Nominal size of rectangular mounting
panel is 2 3/4" by 1 1/2". The holes are 3 1/18" from center to center.
Additional functions can be obtained by connecting customer supplied circuitry to the out-
puts of the microprocessor in the circuit board. These functions include selectable temper-
ature alarms and minimum or maximum readings. For detailed information request Taylor
Precision Products Engineering Bulletin 9940N-TB.
2