Daikin EKRTWA Manual De Instalación página 6

Ocultar thumbs Ver también para EKRTWA:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 49
1D_IM_4PW56101-1.book Page 4 Thursday, August 27, 2009 10:44 AM
7b When connected to the motorized valve, wire the motorized
valve and the thermostat as shown below (for heating-only
applications).
Power supply
X1M
C
com
H
The output relays (H and C) are voltage-free contacts. Refer
to "Technical characteristics" on page 11 for maximum load.
8
Fasten the thermostat with the supplied screws.
Be careful not to pinch the wiring when fastening.
9
Put the transparent cable protection back into place and fix
the cable protection with the screw.
10 Close the thermostat cover.
11 Remove the protective film from the LCD.
Installation manual
4
EKRTWA
Room thermostat
4PW56101-1

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido