EXISTING CONSTRUCTION ASSEMBLY INSTRUCTIONS – ATTIC SPACE NOT ACCESSIBLE
3. If this fan is not replacing an old fan, be sure
to cut a 7-1/2 in. x 7-1/4 in. opening for the
fan housing (A).
4. Remove grille mounting bracket by unscrewing
two screws on each bracket.
NOTE: Save screws for re-installation of fan
motor and grille mounting brackets.
5. With screw removed slide the brackets to the left
and then remove the housing.
Remove the three prong fan plug from the
housing.
With the grille mounting brackets removed, pull the
black fan unit straight out of the metal housing.
6. Pull the house wires through the wire box cover
hole. Using a quick connector, secure 120 V
AC house wiring from the wall switch to the fan
as showen in the wiring diagram on page 5. 14
AWB is the smallest conductor that should be
used for branch-circuit wiring. Please refer to
the wiring diagrams for detail on page 5.
Carefully push the connect wires back into the
wiring box housing. Reattach the wiring box
cover.
CAUTION: If your electrical wires do not match
the colors listed, you must determine what each
house wire represents before connecting. You
may need to consult an electrical contractor to
determine safely.
3
4
5
6
12
Quick
connector
House
Product
wires
wires