If the Error LED on the front of the device lights yellow, there are two possible
causes:
Overheating of the hard drive
The running application cannot be stopped.
A new application cannot be started.
Overheating of the processor
The device will shut down automatically.
When the device has cooled down sufficiently (min. 2 hours), it will boot up
automatically.
Possible causes
The device was not installed with a minimum clearance of 85 mm on both sides.
The ambient temperature is too high. See Section
Measures
1.
Pull the power plug and allow the device to cool down.
2.
Wait for at least 2 hours for the device to cool down.
3.
Check to ensure there is sufficient clearance on both sides of the device.
4.
Measure the ambient temperature. See Section
5.
Connect the power plug again.
6.
Restart the unit.