8.4.1
Connecting control panel CKA4810
8.4.1.1 SISTORE unit
Siemens Building Technologies
Fire Safety & Security Products
All manuals and user guides at all-guides.com
Fig. 13
SISTORE unit – CKA4810 system overview
For a more detailed description of the connections please refer to Section
MX / MX DVD or Section
7
D escription of SISTORE MX 3G / MX 3G DVD.
8 5 H
8 6 H
Prerequisite:
The CKA driver is installed and the icon
Section
9 .3
S ubsequent installation of software components.
8 7 H
8 8 H
1.
Connect the converter between the control panel CKA4810 and the SISTORE
unit (see
F ig. 13). See Section
8 9 H
2.
Configure the COM1A connection on the control panel for use as an RS232
interface.
Further information on this can be found in the instruction manuals for the
control panel CKA4810 and the converter.
3.
Start the SISTORE MX application software.
4.
Switch to configuration mode.
5.
Select the System tab.
6.
Mark the checkbox CCTV keyboard. Further information on this can be found
in the SISTORE MX Configuration Manual.
7.
Click Apply.
The interface for the control panel is enabled.
Connections
Signal
SISTORE unit
9-pin Sub-D socket
A (Rx/Tx +)
2
B (Rx/Tx -)
3
GND
5
RXD
TXD
is displayed in the task bar. See
4
D etails for ordering
.
9 0 H
9 1 H
9 2 H
Converter
Converter
25-pin Sub-D
T +
T -
7
3
2
Installation
6
D escription of SISTORE
8 3 H
8 4 H
CKA4810
9-pin Sub-D plug
5
2
3
29
02.2009