Installation
8.4.2.2 SISTORE Remote View
32
Siemens Building Technologies
Fire Safety & Security Products
All manuals and user guides at all-guides.com
Connections
Signal
A (Rx/Tx +)
B (Rx/Tx -)
GND
CKA4820 interface configuration
Protocol: SIMATRIX RS232 or SIEMENS IVM
Baud rate: 9600
Parity: None
If you want to connect the CKA4820 control panel to a SISTORE via the internal COM1A interface,
install the RS-232C/RS-485 interface converter into the connection line. See Section
control panel CKA4810.
Fig. 16
S ISTORE RemoteView
T
For a more detailed description of the connections please refer to Section
MX / MX DVD or Section
7
D escription of SISTORE MX 3G / MX 3G DVD.
1 1 1 H
1 1 2 H
Prerequisite:
The CKA driver is installed and the icon
Section
9 .3
S ubsequent installation of software components.
1 1 3 H
1 1 4 H
1.
Connect the CKA4820 control panel to the client PC (see
2.
Configure the COM1A connection on the control panel for use as an RS232
interface.
Further information on this can be found in the instruction manual for the
control panel.
3.
Start the SISTORE RemoteView application software.
4.
Switch to configuration mode.
5.
Select the System tab.
SISTORE unit
9-pin Sub-D socket
2
3
5
–
C KA4820 system overview
T
T
is displayed in the task bar. See
CKA4820
9-pin Sub-D plug
5
9
6
8 .4.1
C onnecting
1 0 7 H
1 0 8 H
6
D escription of SISTORE
1 0 9 H
1 1 0 H
F ig. 16).
1 1 5 H
02.2009