Power 541/2; Automatic Limit Switches Setting; Removing The Motor; Troubleshooting - Mottura POWER 541 Manual De Instrucciones, Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
A
L
UTOMATIC
IMIT
The Power 541/2 doesn't require any manual setting of its limit switches. The Power 541/2 automatically sets its
limit switches during the first runs (this happens also the first runs after a blackout).
Removing the motor from the motor pulley is a procedure that demands great care.
Keep all unauthorized persons out of the work zone during this procedure.
Following the instructions in attachment "E" support the motor unit before releasing the lever to prevent it from
dropping under its own weight.
FAULT
The system does not move
The system does not stop at
the correct position
Power requirement: 90 - 250 Vac, 50 - 60 Hz
Input: 30 W
Sliding velocity: 12 cm/s
Radio frequency chip reception frequency: 868 MHz - 915 MHz (Power 541/1)
Single control with SINGLE button (Power 541/1)
Simultaneous control with GROUP button (Power 541/1)
Manufactured to EU standards
Dimensions: 104 mm x 63 mm x 240 mm
Weight: 0,9 Kg
8
M
OTOR WITH
S
WITCHES SETTING
R
EMOVING THE MOTOR
T
POSSIBLE CAUSE
Incorrect wiring
No electrical power
Faulty motor unit
R. F. association not carried out
(Power 541/1)
Obstructions in the curtain
work space
T
C
HARACTERISTICS (
ECHNICAL
P
541/2
OWER
3
90-250 V
WIRES
AC CONTROL
ROUBLESHOOTING
Check and correct the wiring by following
SEE ATTACHMENT
En 4
Z 253/1 rB
REMEDY
the instructions in this manual
Restore electrical power
Request replacement of the motor unit
Carry out the association procedure
(Power 541/1)
Remove obstructions
"E")

Publicidad

Tabla de contenido
loading

Tabla de contenido