Tabla De Contenido; Technical Description; Conditions Of Use - Mottura POWER 541 Manual De Instrucciones, Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
Introduction ......................................................................................................................................... 1

Technical description ............................................................................................................................. 1

Intended use ........................................................................................................................................ 1

Conditions of use .................................................................................................................................. 1

Important safety instructions for installation and use ................................................................................. 2
Assembly and installation ....................................................................................................................... 2
Electrical connections ............................................................................................................................ 2
Power 541/1 ..................................................................................................................................... 2
Power 541/2 ..................................................................................................................................... 2
Power 541/1 ......................................................................................................................................... 3
Control ............................................................................................................................................. 3
Automatic Limit Switches setting ......................................................................................................... 3
Assigning an R. F. radio receiver ......................................................................................................... 3
Power 541/2 ......................................................................................................................................... 4
Automatic Limit Switches setting ......................................................................................................... 4
Removing the motor .............................................................................................................................. 4
Troubleshooting .................................................................................................................................... 4
Technical Characteristics ........................................................................................................................ 4
This manual is an integral part of the product and must be kept for future reference after
installation.
It contains instructions for the correct installation and use of the system.
Follow these instructions carefully to prevent injury to people and damage to property.
The Power 541 is a system for motor-driven draped curtains is designed for indoor use.
The Mottura S.p.A. Quality System is certified under UNI EN ISO 9001:2008 by certification authority DNV, and
guarantees the manufacturing process control.
The Power 541 is an electromechanical system whose mechanical part consists of:
6060 T6 UNI 8278 extruded aluminum alloy
polyurethane drive belt with steel strands and antifriction coating
thermoplastic motor / transmission pulleys
roller sliders to support and move the fabric
The Power 541/1 is operated by a 24 Vdc gear motor with encoder, controlled by a circuit board equipped with
switching power supply, control logic and integrated two-way R. F. receiver.
The Power 541/2 is operated by a 24V DC gear motor with encoder, controlled by a circuit board equipped with
switching power supply and control logic.
The Power 541 system is designed for internal use in homes, businesses, and public buildings as a protection
against solar radiation. It is designed for horizontal installation only. Therefore, any other use is considered as
not conforming to technical specifications, and in such cases the manufacturer will not be liable for any
malfunction, injury to people, or damage to property.
The Power 541 system motor group is not suitable for use in rooms with risk of explosion and in situations
requiring a protection level higher than IP30.
For correct operation, the Power 541 system requires an adequate power supply (tension 90 - 250 Vac and frequency
50 - 60 Hz; see "Electrical connections" section), a structure that is strong enough to support the weight of the
system and the stress to which it is subjected, and room temperature between + 10° C and + 50° C.