Operator's Manual / Manual del Operario
Models / Modelos
074003 & 074004
DO NOT RETURN TO THE STORE NO NECESITA VOLVER A LA TIENDA
Questions? Need help? Before returning this product for any reason
please contact us at:
STOP
¿Tiene preguntas? ¿Necesita ayuda? Antes de devolver el producto
por cualquier razón, póngase en contacto con nosotros:
1-800-743-4115
WARNING
Failure to read and follow the Operator's Manual
and all operating instructions can result in death,
bodily injury, and/or property damage.
Save this manual for future reference.
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
Air Compressor
JEFFERSON,WISCONSIN, U.S.A.
www.brutepower.com
ADVERTENCIA
Si no se leen y siguen las indicaciones del Manual del
Operario y todas las instrucciones de uso, se pueden
producir daños materiales, lesiones o incluso la muerte.
Guarde este manual para futuras consultas.
Manual No. 201303GS
Revision E (10/24/2007)

Publicidad

Capítulos

Tabla de contenido
loading

Resumen de contenidos para Briggs & Stratton Brute 074003

  • Página 1 Air Compressor Operator’s Manual / Manual del Operario Models / Modelos 074003 & 074004 DO NOT RETURN TO THE STORE NO NECESITA VOLVER A LA TIENDA Questions? Need help? Before returning this product for any reason please contact us at: STOP ¿Tiene preguntas? ¿Necesita ayuda? Antes de devolver el producto por cualquier razón, póngase en contacto con nosotros:...
  • Página 2: Tabla De Contenido

    SAFETY RULES SAVE THESE INSTRUCTIONS TABLE OF CONTENTS SAFETY RULES Safety Rules ........2-4 This is the safety alert symbol.
  • Página 3: Safety Rules

    SAFETY RULES WARNING WARNING Hidden internal tank corrosion can cause violent Failure to read and follow instructions in manual explosion leading to severe injury and / or can result in death, bodily injury and / or property property damage. damage. Exceeding pressure rating of attachments or •...
  • Página 4 SAFETY RULES WARNING WARNING Compressed air stream from hose or tank drain Compressed air is not breathable and can cause can cause soft tissue damage to exposed skin and bodily injury. can propel objects leading to severe injury Some paints or solvents may be harmful if inhaled and / or property damage.
  • Página 5: Assembly

    ASSEMBLY ASSEMBLY Place compressor filter housing, filter media, and air filter cover on stem (Figure 2). Secure with washer and wing nut. Figure 2 - Install Air Filter Carton Contents Air Filter • Air compressor Filter Media Stem • Operator’s manual Air Filter •...
  • Página 6 ASSEMBLY Install the Wheel Kit as Follows (Figure 4): WARNING Figure 4 - Install Wheel Kit Residual compressed air in pump can propel oil and cause soft tissue damage to exposed skin or eyes leading to severe injury. • Always wear ANSI Z87.1 approved safety glasses with side shields.
  • Página 7: Features And Controls

    FEATURES AND CONTROLS FEATURES AND CONTROLS Read this Operator’s Manual and safety rules before operating your compressor. Compare this illustration with your air compressor to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. A - Air Compressor Pump: Pump compresses air into J - Safety Valve: Valve protects against excessive tank tank.
  • Página 8: Operation

    OPERATION OPERATION Open drain valve (rotate fully counterclockwise) to prevent air pressure build-up in air tank during break-in period (see Figure 8). Break-In Procedure Figure 8 - Drain Valve in CLOSED Position Before first use of this equipment, the system must undergo a break-in operation, as described in this section.
  • Página 9: Grounding Instructions

    OPERATION Air Compressor Operating Location Make sure power outlet being used has same configuration as air compressor’s plug (see Figure 9). Locate the air compressor in a clean, dry and well-ventilated DO NOT USE A GROUND ADAPTER! area for operation.The air compressor should be placed at least 12 inches (30 cm) away from walls or other Figure 9 - Correctly Rated 15 AMP Power Duplex Outlet obstructions that could interfere with airflow.
  • Página 10: Extension Cords

    OPERATION Starting Your Air Compressor Stopping Your Air Compressor Make sure ON - OFF switch is in OFF position. Push ON - OFF switch to OFF position. Compressor motor will stop. Plug power cord into grounded 120 Volt A.C. outlet (see Figure 9).
  • Página 11: Compressor Operation

    OPERATION Compressor Operation WARNING You do not have to use the maximum operating pressure at Compressed air stream from hose or tank drain all times as the pneumatic tool being used often requires less can cause soft tissue damage to exposed skin and pressure.
  • Página 12: Specifications

    SPECIFICATIONS / MAINTENANCE PRODUCT SPECIFICATIONS AC Frequency: ....... . . 60Hz Tank capacity Rated AC Voltage: .
  • Página 13: Cleaning Unit

    MAINTENANCE Check Safety Valve Inspect Pump Oil Level Pull ring on safety valve (see Figure 11) and observe that Inspecting Pump Oil Level safety valve operates freely. Use these steps to inspect oil level: Figure 11 - Safety Valve Place unit on a flat, level surface. Carefully observe sight glass and verify that oil level is at proper level (see Figure 12).
  • Página 14 MAINTENANCE • Louvers on left hand end of motor shroud (when Remove air filter media. viewed from rear of unit (see Figure 13). IMPORTANT: DO NOT operate compressor with air filter media removed. Figure 13 - Cooling Fins WARNING Cooling Fins Compressed air stream from hose or tank drain can cause soft tissue damage to exposed skin and can propel objects leading to severe injury...
  • Página 15: Storage

    MAINTENANCE / STORAGE Using oil funnel, slowly add recommended oil.Visually Also see the Troubleshooting section on pages 16-17 for inspect oil level frequently at sight glass to avoid more information. overfilling air compressor pump (see Figure 15). STORAGE Figure 15 - Pump Oil Fill Information Before you store your air compressor, make sure you Oil Breather Cap perform the following:...
  • Página 16: Troubleshooting

    TROUBLESHOOTING TROUBLESHOOTING Before You Call If you have any problems with the operation of your air compressor, please call the air compressor helpline at 1-800-743-4115. If calling for assistance, please have the model, revision, and serial number information printed on the data tag available.
  • Página 17 TROUBLESHOOTING PROBLEM CAUSE CORRECTION Prolonged excessive use of air. Decrease amount of air used. Compressor is not large enough for air Check the accessory requirement. If it is requirement. higher than the CFM or pressure supplied by your air compressor, you need a larger Compressor is not capacity air compressor.
  • Página 18: Glossary

    GLOSSARY GLOSSARY Becoming familiar with these terms will help you understand Cut-Out Pressure – While the compressor is running, air is and operate most air compressors: being produced and stored in the air tank. If no air is being used, air pressure will build in the tank.The pressure switch Air Delivery –...
  • Página 19: Warranty Period

    BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC AIR COMPRESSOR OWNER WARRANTY POLICY Effective July 1, 2006 replaces all undated Warranties and all Warranties dated before July 1, 2006 LIMITED WARRANTY Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the air compressor that is defective in material or workmanship or both.
  • Página 20: Descripción Del Equipo

    REGLAS DE SEGURIDAD CONSERVE ESTAS INSTRUCCIONES TABLA DE CONTENIDOS REGLAS DE SEGURIDAD Reglas de seguridad ........20-22 Éste es el símbolo de alerta de seguridad.
  • Página 21: Reglas De Seguridad

    REGLAS DE SEGURIDAD ADVERTENCIA ADVERTENCIA La corrosión interna y oculta del tanque puede Si no se leen y siguen las instrucciones del manual, se provocar una explosión violenta con el resultado de pueden producir daños materiales, lesiones o incluso la lesiones y/o daños materiales de gravedad.
  • Página 22 REGLAS DE SEGURIDAD ADVERTENCIA ADVERTENCIA La corriente de aire comprimido procedente de la El aire comprimido no es respirable y puede provocar manguera o del punto de vaciado del depósito puede lesiones. provocar lesiones de los tejidos blandos en las partes La inhalación o digestión de algunos disolventes y expuestas de la piel y propulsar objetos, con el pinturas puede provocar náuseas, desmayos o...
  • Página 23: Montaje

    MONTAJE MONTAJE Coloque el cuerpo del filtro del compresor, el material filtrante y la tapa del filtro de aire en la boquilla. Fije el conjunto con una arandela y una tuerca de mariposa. Contenido de la caja • Compresor de aire Figura 18 - Instalado el filtro de aire •...
  • Página 24: Añadir Aceite Y Instalación Del Tapón Del Respirador Del Aceite De La Bomba

    MONTAJE Monte el juego de ruedas como se indica a continuación ADVERTENCIA (Figura 20): El aire comprimido residual de la bomba puede impulsar Figura 20 - Monte el juego de ruedas el aceite y provocar lesiones de los tejidos blandos en las partes expuestas de la piel o de los ojos, lo que puede resultar en daños de gravedad.
  • Página 25: Características Y Mandos

    CARACTERÍSTICAS Y MANDOS CARACTERÍSTICAS Y MANDOS Lea este Manual del Operario y las normas de seguridad antes de utilizar el compresor. Compare esta ilustración con el compresor de aire para familiarizarse con la situación de los distintos mandos y ajustes. Guarde este manual para futuras consultas.
  • Página 26: Operación

    OPERACIÓN OPERACIÓN Una vez transcurridos 15 minutos, cierre válvula de vaciado (gire a tope hacia la derecha). El depósito de aire se llenará hasta alcanzar la presión de “corte” y el compresor se Procedimiento de preparación para el uso detendrá. inicial NOTA: Compruebe el nivel de aceite del compresor después de la preparación para el uso inicial.
  • Página 27: Puesta En Marcha Del Compresor De Aire

    OPERACIÓN Examine el cable y el enchufe antes de cada uso. NO utilice el Parada del compresor de aire compresor si presenta signos de deterioro. Sitúe el interruptor ON - OFF en la posición OFF. El motor Si no comprende perfectamente estas instrucciones de del compresor se detendrá.
  • Página 28: Uso Del Compresor

    OPERACIÓN Uso del compresor ADVERTENCIA No es necesario utilizar en todo momento la máxima presión de La corriente de aire comprimido procedente de la trabajo, ya que las herramientas neumáticas suelen necesitar una manguera o del punto de vaciado del depósito puede presión inferior.
  • Página 29: Especificaciones

    ESPECIFICACIONES / MANTENIMIENTO ESPECIFICACIONES Capacidad del depósito Modelo 074004 ......37,8 l (10 galones) Frecuencia CA: ........60 Hz Modelo 074003 .
  • Página 30 MANTENIMIENTO Comprobar la válvula de seguridad Inspeccione el nivel de la bomba de aceite Tire de la anilla de la válvula de seguridad (Figura 27) y Inspección del nivel de la bomba de aceite compruebe si la válvula funciona libremente. Siga estos pasos para revisar el nivel de aceite: Figura 27 - Válvula de seguridad Coloque la unidad en una superficie plana y nivelada.
  • Página 31: Comprobar / Limpiar El Filtro De Aire

    MANTENIMIENTO • Rejillas situadas en el extremo izquierdo de la cubierta del Retire el material filtrante. motor (vista desde la pare trasera de la unidad, consulte la IMPORTANTE: NO utilice el compresor sin el filtro de aire Figura 29). instalado. Figura 29 - Aletas de refrigeración ADVERTENCIA Aletas de...
  • Página 32: Almacenamiento

    MANTENIMIENTO / ALMACENAMIENTO Vacíe todo el aceite en el recipiente. Coloque el tapón de Para obtener más información, consulte también la sección vaciado y apriételo con la llave ajustable. Deseche el aceite DIAGNOSITICOS DE AVERÍAS en la páginas 33-34. usado con arreglo a la normativa vigente. ALMACENAMIENTO Con la ayuda de un embudo, añada lentamente el aceite recomendado.
  • Página 33: Diagnosticos De Averías

    DIAGNOSITICOS DE AVERÍAS DIAGNOSITICOS DE AVERÍAS Antes de llamar Si tiene algún problema con el funcionamiento del compresor de aire, llame a la línea de asistencia 1-800-743-4115.Tenga preparados los números de modelo, revisión y serie, que figuran en la etiqueta de datos.
  • Página 34 DIAGNOSITICOS DE AVERÍAS PROBLEMO ACCION CAUSA Uso excesivamente prolongado del aire. Reduzca la cantidad de aire utilizada. La capacidad del compresor es Compruebe los requisitos del accesorio. Si insuficiente para generar el caudal de superan los CFM o la presión que suministra aire necesario.
  • Página 35: Glosario

    GLOSARIO GLOSARIO La familiarización con los siguientes términos le ayudará a GFCI – Interruptor de corriente de fallo de conexión a tierra. comprender y utilizar mejor el compresor de aire: Dispositivo que detecta un flujo de corriente en la gama de los miliamperios en un circuito eléctrico de conexión a tierra y activa Aisladores antivibración –...
  • Página 36: Garantía Limitada

    POLÍTICA DE GARANTÍA PARA EL PROPIETARIO DE COMPRESORES DE AIRE BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC Fecha de entrada en vigor: 1 de octubre de 2005. Sustituye a todas las garantías sin fecha y a las de fecha anterior al 1 de octubre de 2005 GARANTÍA LIMITADA Briggs &...