Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6.
Using oil funnel, slowly add recommended oil.Visually
inspect oil level frequently at sight glass to avoid
overfilling air compressor pump (see Figure 15).
Figure 15 - Pump Oil Fill Information
7.
When oil is at proper level, reinstall oil breather cap and
wipe up any spilled oil.
Check Pump Intake and Exhaust
Valves
Once each year, certain internal compressor components
must be inspected. Have a trained service technician perform
this check, to include the air compressor pump intake and
exhaust valves.
Check Safety Labels
As often as desired or at least yearly, inspect all labels applied
to the air compressor. All safety labels should be present and
readable. Should any safety label be missing or illegible, obtain
a replacement from an authorized service center or call the
air compressor helpline at 1-800-743-4115.
Overload Protection Reset
This compressor is equipped with an overload protection
feature that protects the motor if it overheats. If the
compressor motor overheats and 'trips' this circuit breaker,
wait 15 minutes for the motor to cool.Then push the RESET
button located on the motor shroud (see Figure 16).
Figure 16 - Overload Protection RESET Button
Oil Breather Cap
Oil Fill
Location
MAXIMUM
Oil Level
PROPER
Oil Level
Oil Drain Plug
RESET Button
MAINTENANCE / STORAGE
Also see the Troubleshooting section on pages 16-17 for
more information.

STORAGE

Before you store your air compressor, make sure you
perform the following:
1.
Review "Maintenance" beginning on page 12 and perform
scheduled maintenance as necessary.
2.
Push ON - OFF switch to OFF and unplug unit.
3.
Turn pressure control knob counterclockwise until knob
turns freely.
4.
Remove air tool or accessory.
5.
Pull ring on safety valve and drain air from air tank to
reduce air pressure. Release safety valve ring.
WARNING
Compressed air stream from hose or tank drain
can cause soft tissue damage to exposed skin and
can propel objects leading to severe injury
and / or property damage.
• DO NOT direct air stream at self or others.
• Always wear ANSI Z87.1 approved safety glasses with side
shields.
6.
Drain remaining air and water from tank by opening
drain valve fully counterclockwise.
7.
Rock unit forward and back to agitate condensate as it
drains to obtain a more thorough emptying action.
8.
After water has been drained, close drain valve fully
clockwise.
9.
Protect electrical cord and air hose from damage (such
as being stepped on or driven over).
10. Store air compressor in clean, dry, indoor location.
15

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Brute 074004

Tabla de contenido