SPECIFICATIONS
Ranges
Full Scale
1,9999 mΩ
19,999 mΩ
199,99 mΩ
1,9999 Ω
19,999 Ω
199,99 Ω
1999,9 Ω
Display
Measurement
Range and Safety
Measurement
Mode
Control
Speed
Test Method
Test Current Accuracy
Output Current Stability
Resolution
Accuracy
0,1 µΩ
±0,2%±0,2 µΩ
1 µΩ
±0,2%±2 µΩ
10 µΩ
±0,2%±20 µΩ
100 µΩ
±0,2%±0,2 mΩ
1 mΩ
±0,2%±2 mΩ
10 mΩ
±0,2%±20 mΩ
100 mΩ
±0.2%±0.2 Ω
DLRO 10
4
/
digit seven segment LED
1
2
LED Indication
Manual, Auto, Continuous, Inductive
Fully Automatic
<3s for forward & reverse current and to display average
Single cycle reversing d.c. ratiometric measurements and average result calculated.
10%
<10 ppm per second @ 10 mA
<100 ppm per second at higher currents
Full Scale Volts
Resistance
Induction
20 mV
20 mV
20 mV
20 mV
200 mV
20 mV
200 mV
20 mV
200 mV
20 mV
200 mV
200 mV
200 mV
DLRO 10X
Manual, Auto, Continuous,
Inductive, Unidirectional.
Fully Automatic with manual
override of maximum current
Test Current
Resistance
Induction
10 A
1 A
1 A
100 mA
1 A
10 mA
100 mA
1 mA
10 mA
100 µA
1 mA
100 µA
100 µA
Large backlit LCD
19