The pod enters with difficulty
and does not locate correctly.
The coffee delivery is regular
but the stroke counter fails to
signal the output.
Water leakage inside the
apparatus.
• The pod drawer is full: the
excess pods are blocked
along the discharge conduit.
The FAP press remains lowered
• The electrovalve does not
discharge.
• The stainless steel spring in
the chamber is broken.
• The jaws are blocked by an
excesss of coffee powder.
• The stroke counter is faulty.
• The connector is
disconnected.
• The electronic card is
defective.
If a leakage occurs between
the FAP press and chamber.
• Perforated membrane.
If a leakage occurs between
the chamber and the
teflon-coated plate.
• Presence of limescale.
• Membrane damaged on
the seal with the collar of
the teflon-coated plate.
If a leakage occurs between
the teflon-coated plate and the
stainless steel labyrinth:
• Damaged or pinched
rectangular gasket.
If a leakage occurs between
the stainless steel labyrinth and
the top-plate.
• Labyrinth faulty or cracked.
In the event of faults
• Remove the drawer and
clean it.
• Remove all the pods that
have fallen outside the
drawer.
• Replace the component.
• Dismantle the output unit
and undertake cleaning of
the slide-base and jaws.
• Replace the component.
• Check the electrical
connections.
• Replace the component.
• Dismantle the heater and
replace the membrane.
• Dismantle the unit, remove
the scale and replace the
membrane.
• Dismantle the unit and
replace the gasket.
• Replace the labyrinth and
gasket.