set temperature and displays this value. Constant illumination means that the System
is overheating. The blinking light Signals that the operating ternperature has been
reached.
The digital display (2) Shows the actual value temperature. By pressing the UP or DOWN
key (3, 4) the digital display (2) switches to the setpoint. The setpoint tan be changed
by tapping or by firmly pressing the UP or DOWN button (3,4) in the desired direction.
Pressing the button will Change the setpoint quickly. The digital display (2) returns
automatically to the actual value approximately 2 seconds after releasing the button.
Maintenance
The transition between the heating element / Sensor and the tip of the soldering iron
may not come in contact with dirt, foreign particles or become damaged. since this
3. Equipotential bonding
The various circuit elements of the 3.5 mm jack bush make 4 variations possible:
Hard-grounded:
No plug (delivery form)
Equipotential bonding:
With plug, equalizer at Center contact (impedance 0 Ohms)
With plug and soldered resistance. Grounding via set
resistance value.
or
No plug and Separation of bridge Bl on the control board.
Grounding via RC filter 100 k ohms / nF
4. Instructions for use
or dirt on the tip which may have occurred during storage. During pauses between
soldering and before storing the soldering iron, ensure that the tip of the soldering iron
is well coated. D
not use aggressive fluxing agents.
O
Note: Always ensure the proper Position of the soldering iron tip.
These soldering irons have been adjusted for an average-size tip. Deviations tan occur
due to exchanging of the tip or using other tip designs.
Extemal inaut unit WCB 1 and WC6 2 (oational)
The followina functions are possible when using an external input unit.
Offset:
The real temperature of the soldering iron tan be changed by 2 20 " C
by input of a temperature offset.
has switched to standby mode.
the soldering Station has been locked.
Switching the temperature display from "C to "F, and vice versa.
Window:
Setting a temperature window (only with contra1 units with Optical
coupler output). If the actual temperature is within the temperature
window, a potential-free contact (Optical coupler output) will be
switched through.
Cal:
Re-adjustment of the soldering Station (WCB 2 only).
PC interface:
Temp. gauge:
Integrated temperature gauge forthermal element Type K (WCB 2
only).
5. Safety instructions
The manufacturer assumes no liability for uses other than those described in the
operating instructions, or for unauthorized alterations.
These operating instructions and warnings should be read carefully and kept in an
easily visible location in the vicinity of the soldering iron. Non-observance of these
warnings tan result in accidents, injury or risks to health.
24