I
NSTALLATION OF THE HEATER KIT
CAUTION
The heater kit can only be installed and used in
combination with the RKHBRD indoor unit.
The heater of the heater kit can only be connected to
the space heating water outlet of the RKHBRD indoor
unit. Other connections are not allowed.
Only one heater kit can be connected to the RKHBRD
indoor unit. It is not allowed to combine multiple
heater kits in series or parallel.

Selecting an installation location

The heater kit is to be wall mounted in an indoor location that meets
the following requirements:
The installation location is frost-free.
The space around the heater kit is adequate for servicing. (See
figure 4).
The space around the heater kit allows for sufficient air
circulation.
The installation surface is a flat and vertical non-combustible
wall, capable of supporting the operation weight of the heater kit.
There is no danger of fire due to leakage of inflammable gas.
All piping lengths and distances have been taken into
consideration.
Requirement
Maximum allowable distance between the heater kit
and the indoor unit.
During normal operation the heater kit will produce sound which
could be observed as noise. The sound origin can be contactor
activation. Therefore it is advisable to install the heater kit on a
firm wall and not in nor close to a sound sensitive environment
(e.g. bedroom).
Do not install the heater kit in places with high humidity (e.g.
bathroom).
The equipment is not intended for use in a potentially explosive
atmosphere.
Do not install the heater kit in places often used as work place.
In case of construction works (e.g. grinding works) where a lot of
dust is created, the heater kit must be covered.
Take care that in the event of a water leak, water can not cause
any damage to the installation space and surroundings.
Do not place any objects or equipment on top of the heater kit.
Make sure that there are no external magnetic fields in the
immediate vicinity of the flow switch, since these can impair
device functioning.

Dimensions and service space

Unit of measurement: mm.
Dimensions of the heater kit, see figure 3.
Required service space, see figure 4.
RKBUHAA6V3+W1
Heater kit for air to water heat pump system
4PW58904-1

Installing the heater kit

At delivery, the heater kit must be checked and any damage
must be reported immediately to the carrier claims agent.
Check if all heater kit accessories (see "Accessories" on page 2)
are enclosed.
1
Mark the fixation positions on the wall (2 on top and 2 at the
bottom).
Make sure that the marks (2 by 2) are completely level and the
dimensions of the marks are corresponding according to
figure 2.
When the heater kit is not installed level, air might get trapped in
the water circuit resulting in malfunctioning of the heater.
2
Drill 4 holes and install 4 plugs (suitable for M6).
Plugs and screws are field supply.
3
Put the screws in the top plugs and hang the heater kit on the
top screws.
4
Put the screws in the bottom plugs and fix the 4 screws firmly.
1
1
Value
10 m
1
1
2
Installation and operation manual
3
4
4

Publicidad