The fuse (8A or in case of the 14A version: 15A) must
then be replaced.
To replace the fuse, go through the following steps
(NOTE: The fuse holder is placed on the left front side of
the controller to the left of the socket. The fuse of the
fuse holder in the centre of the Clima Control Plus is for
the heater and is always 15 A):
1. Press the black fuse holder slightly with a
screwdriver and turn it a quarter of a turn
counterclockwise.
2. Remove the fuse holder.
3. Remove the fuse.
4. Insert a new 8 or 15 amp fuse (depending on the
version of your Clima Control Plus).
5. Reinstall the fuse holder in the housing of the Clima
Control Plus.
6. Then press the fuse holder again with a screwdriver
and tighten it by turning it a quarter turn clockwise.
Your Clima Control Plus is ready for use again.
If the fuse of the fan or heater is defective, the Clima
Control Plus itself and any connected devices (Sensor,
Datalogger) will continue to operate.
____________________________________________________________________________________________________________________________
TechGrow
| Innovative Growing Solutions
26