Turn the PTK to select the desired degree of correction.
Press the PTK to confirm.
10.4 Set night delay
This function allows you to adjust the bridging time
between the moment that the light goes out and the
night temperature is valid. During this period the fan will
not start to run faster.
Select "Night delay" in the TMP menu and press the PTK.
Overtemp 32.0°
=> Temp offset 0.0°
Night delay
5m
>> NEXT >>
Turn the PTK to select the desired time delay (up to 60
minutes).
Press the PTK to confirm.
10.5 Minimum/maximum temperature values
Select >> NEXT >> on the second page of the TMP
menu and press the PTK.
Overtemp 34.0°
Temp offset 0.0°
Night delay
5m
=> >> NEXT >>
Now you can read the minimum/maximum temperature
values. To reset these values, select "Reset min/max" and
press the PTK.
TMP Min
26.2°C
TMP Max 33.6°C
Reset min/max
>> NEXT >>
Select >> NEXT >> and press the PTK to return to the
main screen.
11. Relative Humidity (RH) settings
If an RH sensor is connected to the Clima Control Plus,
you can set the desired relative humidity level. By
default the RH values for day and night are off
____________________________________________________________________________________________________________________________
TechGrow
| Innovative Growing Solutions
("Humidity day" and "Humidity night" are set to "Off").
You can adjust these settings in the following way.
You are in the main screen. Select "RH" and press the
PTK.
TMP = 33.6 °C
=> RH =
66%
BOX =
90%
CO2 = 1112 PPM
=> Humidity day Off
Hum. night
Off
Humidity +/- 5%
>> NEXT >>
Select "Humidity day" to set the desired level during the
day. Press the PTK to confirm.
If you want to completely disable air humidity regulation
during the day, set the value to "Off" again.
=> Humidity day 60%
Hum. night
Off
Humidity +/-
5%
>> NEXT >>
Select "Hum. night "and turn the PTK to set the desired
level. Confirm by pressing the PTK.
If you want to completely disable air humidity regulation
during the night, set to "Off".
Humidity day 60%
=> Hum. night
60%
Humidity +/-
5%
>> NEXT >>
11.1 Set hysteresis RH
The hysteresis is set to +/- 5% by default. To adjust the
setting, select "Humidity +/-" and turn the PTK. Confirm
by pressing the PTK.
24