Troubleshooting - DAB M/T 1.0 Instrucciones Para La Instalacion Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 102
Restoring the factory settings
(keys SET and + for 2 seconds when switching on)
EE
Saving and reading the factory settings on the EEprom
Error and status conditions
bL
Shutdown due to low water level
bP
Shutdown due to absence of pressure sensor
LP-E1
Shutdown due to low supply voltage
HP
Shutdown due to high supply voltage
ot
Shutdown due to overheating of the power stages
oC
Shutdown due to current overload in the electric pump motor
oF
Shutdown due to current overload in the output stages
SC
Shutdown due to short circuit in the output stages
Shutdown due to non setting of the rated current (rC) or of the rated
EC
frequency (Fn)
E0...E7
Internal error 0...7
F1
Status / Alarm input 1
F3
Status / Alarm input 3

1.21 TROUBLESHOOTING

A.D. messages
EC
bL
oF
oC
E1 or LP
Sb or Go
Flashing lights
bP
SC
ENGLISH
Description
Possible cause
Pump current (rC) not set
1) No water
2) Pump not primed
3) Direction of rotation inverted
1) Excessive power absorption
2) Pump blocked
1)
Pump
current
(rC)
incorrectly
2) Pump blocked
1) Low power supply voltage
2) Excessive voltage drop on line
No communication
Pressure sensor disconnected
Short circuit between phases
Table 9 Troubleshooting.
A.D.
M/T 1.0
Set parameter rC
1-2) Prime the pump and ensure that there are no air
bubbles in pipelines. Check that suction and any filters are
not obstructed Check that the pipeline from the pump to the
A.D. is not damaged or leaks significantly.
3) Check the direction of rotation, parameter rt
1) Check the type of connection; star or delta.
Check the direction of rotation, parameter rt
Check that the motor does not absorb current levels
exceeding the max. supply of A.D.
2) Check that the impeller or motor is not blocked or
obstructed by foreign bodies. Check the motor connection
phases
1) Set rC with the current according to the type of
connection (star or delta) as stated on the motor dataplate.
set
Check the direction of rotation, parameter rt
2) Check that the impeller or motor is not blocked or
obstructed by foreign bodies. Check the motor connection
phases
1) Ensure correct line voltage
2) Ensure correct section of the power cables
Check correct setting of parameter Ad. Ensure that the
interconnection cable is connected and intact.
Check correct positioning of the connections on the
connector pins
Check the pressure sensor cable connection
Ensure that the motor is in working condition and check all
relative connections
57
Factory parameters
A.D.
A.D.
M/T 2.2
T/T 3.0
Remedy
A.D.
T/T 5.5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

M/t 2.2T/t 3.0T/t 5.5

Tabla de contenido