Checking the GFCI

Testing can only be performed while the thermostat is calling for
heat.
Adjust the setpoint until the heating symbol (
Up button to increase the heating demand and then press the OK
button Wait 10 seconds to allow the thermostat to adjust to the
new setpoint.
Then press the TEST button on the top of the thermostat.
The test is successful if the red light in the TEST button lights up
and GROUND FAULT is shown on the display. If this does not oc-
cur, check the installation/contact your electrical installer.
Press the Standby/Reset button to reset the GFCI.
The red light should go out and the display returns to normal ap-
pearance.
Press the Down button to return to the original temperature setting.
If the test fails, check the heating cable and thermostat.
If during normal operation the GFCI trips without the TEST button
being pressed, there could be a ground fault! To check whether it
is a ground fault or nuisance tripping, press Standby/Reset.
If this causes the red light to go off and stay off, it was nuisance
tripping and the system is operating correctly. If this does not oc-
cur, there is a ground fault! Contact your electrical installer.

4-Event Program

I want the temperature to be controlled automati-
cally in accordance with a program of individual
temperature settings for four separate events during
a day:
• when I wake up in the morning,
• when I am away at work,
• when I come home,
• and at night.
To do so, you must perform the following 3 steps:
Step 1: Select automatic temperature control.
1
Press the OK button to activate the menu.
2
Press the Up or Down buttons until the Mode option fl ashes.
3
Press the OK button.
4
Press the Up or Down buttons until the Auto options fl ashes
in the upper part of the display.
5
Press the OK button.
Factory setting: Auto mode
AUTO
OVERRIDE
MAN. MODE
MODE
SCHEDULE
PROGRAM
SETTINGS
EXIT
Step 2: Choosing the weekly schedule
for your program.
You have the following options:
5:2 will give you 5 days (Monday to Friday) with the same four
events (Morning, Out, Home, Night) and 2 days (Saturday and
Sunday) with the same two events (Morning and Night).
2
6:1 will give you 6 days (Monday to Saturday) with the same
four events (Morning, Out, Home, Night) and 1 day (Sunday)
with the same two events (Day and Night).
) appears. Use the
7:0 will give you individual settings for each day from Monday
to Sunday.
Step 3: Select the time and temperature settings for
each event in the program of days selected in the
previous step.
At work
Morning
Please note: The following description illustrates an example in
which settings are made for the daily events in a 5:2 program.
© 2009 Danfoss Inc.
1
Press the OK button to activate the menu.
2
Press the Up or Down buttons until the Schedule option fl ashes.
3
Press the OK button.
4
Press the Up or Down buttons until the required program (5:2,
6:1 or 7:0) fl ashes in the lower part of the display.
5
Press the OK button.
SCHEDULE
SET TEMP
PROGRAM
Hour
Minutes
1
Press the Up or Down buttons until the Program option fl ashes.
2
Press the OK button.
3
Press the Up or Down buttons until the day(s) that you wish
to program fl ash in the lower part of the display, e.g. Mon Tue
Wed Thu Fri.
4
Press the OK button. The symbol for the fi rst event (e.g. morn-
ing) will now fl ash.
5
Press the OK button. The hour will fl ash, allowing you to set
the hour at which you want the morning period to begin.
6
Press the Up or Down buttons until the required hour is dis-
played.
7
Press the OK button. The minutes will fl ash.
8
Press the Up or Down buttons until the required minutes are
displayed.
English
MON
TUE WED THU
FRI
EXIT
MON
TUE WED THU
FRI
5-day period
At home
Night