Multiplex MULTIcharger LN-5014 Instrucciones página 7

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

9. Lead-acid battery mode
PB.
10. Screen displays
Displays during charging or discharging
INPUT
BATTERY
VOLTAGE ERROR
OUTPUT
BATTERY
REVERSE POLARITY
Display after charge termination
END
030:00
00000
NC
100mA
10.75V
Display of current values
INPUT
= 12.00V
OUTPUT = 13.18V
If you hold the BATTERY TYPE button pressed in for longer than three seconds, the displays shown above appear, giving the current
values for the battery and the charge process. You can switch between the three windows using the INC and DEC buttons.
If you do not press any button for longer than about three seconds, the screen reverts to the normal display.
11. Error messages
INPUT
BATTERY
Input voltage below 11.0 V or above 15.0 V
VOLTAGE ERROR
OUTPUT
BATTERY
Battery connected to the charger with reversed polarity
REVERSE POLARITY
CHECK THE BATT.
Break in charge circuit
OPEN CIRCUIT
NO BATTERY
No battery connected to the charger's output
OUTPUT CIRCUIT
Internal error in charger
PROBLEM
MULTIPLEX Modellsport GmbH & Co.KG • Neuer Weg 2 • D-75223 Niefern-Öschelbronn • www.multiplex-rc.de
Operating Instructions MULTIcharger LN-5014
If you press the ENTER button briefly while these messages are displayed, it is possible
to alter the existing values.
If you hold the ENTER button pressed in while these messages are displayed, the
charge or discharge process is halted
Pressing the ENTER button while this message is displayed returns you to the main
menu.
ChgCAPA=00000mAh
DchCAPA=00000mAh
CHG PEAK = 12.00V
DCHG AVR = 13.18V

Publicidad

Tabla de contenido
loading

Tabla de contenido