Electrical heating coil for CDF/CDP/CDP-T dehumidifier
Introduction
Part numbers
Overview
Tools needed
Content
Technical data
This section gives all nescessary information on how to install and use the electrical heating
coil for Dantherm CDF/CDP/CDP-T Dehumidifiers.
Electrical heating coil for CDF/CDP/CDP-T 40: 094336
Electrical heating coil for CDF/CDP/CDP-T 50: 094337
Electrical heating coil for CDF/CDP/CDP-T 70: 094338
The heating surface is an accessory for the CDF, CDP and CDP-T ranges and supply additio-
nal heat to the dehumidified air from the dehumidifier.
Flat
Shown below are the components included in the electical heating coil kit.
Fuse
Electrical heating coil
Electrical heater for CDF/CDP/CDP-T 40
Electrical heater for CDF/CDP/CDP-T 50
Electrical heater for CDF/CDP/CDP-T 70
* Maximum current in one single phase
TX20
Relays
Termnal rail blocks
Bridges
2x TX20
Wires
Heating Coil
Power
2 kW
3,5 kW
5 kW
Total max. load
Current
230 VAC
3x 400 VAC
8,7 A
16,2 A
7,5 A*
15,2 A
22,8 A
7,6 A*
21,8 A
29,3 A
10,9 A*