FUNCTION
Control
Detection temperature < setting temperature - 0.5°C, output turns on, and output icon displays.
Specifications
Detection temperature ≥ setting temperature + 0.5°C, output turns off, and output icon disappears.
When power on, thermostat displays "OFF" all outputs are forced off. Touch P3 button to switch (manual/off/auto) mode, then press
On/Off
P2 to confirm and proceed power on/off setting. After power on, device displays current week, local time, working mode, current
Operation
temperature, output status etc. Note: After the backlit goes out, please press the button to light up the backlit first, then press the
button again for corresponding operation.
In normal working status, press P4 or P5 button will enter into temperature setting interface. The setting range is 5-37 °C(41-99°F).
Then press P4 or P5 can adjust the value. Press P3 or wait 25 seconds without any key operation will save the setting and return back
Temperature
to the normal operation interface. Auto Mode: The changed value only valid in the current time period for this time, and the device will
Setting
not effect the preset time period value . Manual Mode: The changed value will be valid until next setting. Vacation Mode: The changed
value will be valid until next setting.
In normal display interface, touch P3 button can switch between Manual and Auto mode. Choose the mode you may need and press
Manual/Auto
P2 button to save the setting. Auto Mode: Device will follow the preset time periods and temperature to control heating system
mode setting
automatically. Manual Mode: Device will follow the manual setting temperature to control the heating system.
In normal display interface, touch P3 button can switch between Manual and Auto mode. Choose the mode you may need. In normal
Auto mode
working interface, short press P1 to enter into time periods setting. Four time periods can be set for each day of the whole week.
time periods
Press P2 can switch among "Hours, Minutes, Temperature value". Press P4 or P5 can change the value. After finished the setting of
parameter
4 time periods on Monday, press P1 and follow the same way to set periods of next days. After all periods set, press P1 will save the
setting
setting and return to normal display. Device will operate in accordance with the new setting.
In normal working interface, long press P1 to enter into local time setting interface. In local time setting interface, press P4 or P5 but-
Local time
ton to set the "week, hour & minute" parameter, and press P1 button can switch among the "week, hour & minute". After finish the local
setting*
time setting, press P1 or wait 25 seconds without any key operation will save the setting and return to normal play.
Humidity
In normal working interface, long press P1+P5 buttons and enter into humidity display interface, when press P1+P5 buttons again, it will
display
back to the normal interface.
operation
In normal working interface, if vocation mode is not activated, long press P2 button to enter vacation mode temperature setting. The
Vacation
default temperature is 10 °C, and setting range is 5-37 °C(41-98°F). Press P4 or P5 to adjust the value, then press P3 to save the setting
mode setting
and return to the normal working interface. In this time vacation mode icon displays, and device will follow the setting. Long press P2
again will end vacation mode and resume to normal work, vacation mode icon will be disappeared.
In shutdown interface: When the built-in temperature sensor detect the temperature value ≤5°C, device will open antifreeze protec-
Antifreeze
tion, electric heating will be forced open, and antifreeze protection icon displays. When the built-in temperature sensor detect the
protection
temperature value>8 °C, device will turn off antifreeze protection and return to normal work, antifreeze icon disappears.
function
Network
To delete the network indicator intermittency you have to press P5 for 10 seconds.
indicator
Factory
To reset the factory values, press P5 for 30 sec. The thermostat will turn off and on again with the factory values.
values
(*) In case of having a HUB iO Simon socket, the time and the day of the week will be updated automatically when you sign up on the iO Simon network.
The thermostat allows you to make some settings as your time parameters through the time push button. And a series of configurations through a menu
accessible from the thermostat buttons. To access the settings menu, set the thermostat to OFF Mode and then press P3 + P5 for more than 2 seconds.
Mediate P4, P5 locate the values and with P3 move between digits. The access code to the menu is 1234. The configurations accessible from this menu are:
MENU
P01
Setpoint maximum possible
P02
Setpoint minimum possible
P03
Time format
P04
Temperature difference to deactivate heating
P05
Temperature difference to activate heating
P06
Anti frost temperature
P07
Equipment status when feeding
P08
Temperature reading time
P09
Temperature setting
P10
Keyboard sound
P11
Light level at rest
P12
Temperature in Celsius or Fahrenheit
THERMOSTAT CONFIGURATION WITHOUT Z-WAVE
WHAT DOES IT SET
PARAMETER
ASSOCIATED PARAMETER
35
36
-
-
-
-
17
-
37
-
3
30
DEFAULT VALUES
37.0
5.0
24
0.5
0.5
5
OFF
2
0
3
2
C
7