This product can be included and managed in a Z-Wave network, working with Z-Wave certified devices and applications from other manufacturers. All
non-battery devices act as repeaters within the Z-Wave network in order to increase the reliability of the network. This product and meets the Z-Wave
Plus safety standards with S2 safety.
CC THERMOSTAT MODE ADMITTED
The device is stopped and does not work
THERMOSTAT_MODE_OFF
The device is active working with the
THERMOSTAT_MODE_HEAT
Setpoint set for heat
The device is active working according
THERMOSTAT_MODE_AUTO
to schedule parameters
The device is active working in low
THERMOSTAT_MODE_
power mode with a reduced SetPoint
AWAY_HEATING
temperature
COMMAND CLASSES SUPPORTED
CC_ASSOCIATION_GRP_INFO_V3
CC_ASSOCIATION_V2
CC_BASIC_V1
CC_CONFIGURATION_V2
CC_DEVICE_RESET_LOCALLY_V1
CC_FIRMWARE_UPDATE_MD_4
CC_MANUFACTURER_SPECIFIC_V2
CC_POWERLEVEL_V1
CC_SECURITY_S2
CC_SENSOR_MULTILEVEL_V5
CC_SUPERVISION
CC_THERMOSTAT_MODE_V2
CC_THERMOSTAT_OPERATING_STATE_V1
CC_THERMOSTAT_SETPOINT_V3
CC_TIME_PARAMETERSV1
CC_TIME_V1
CC_TRANSPORT_SERVICE_V2
CC_VERSION_V2
CC_ZWAVEPLUS_INFO_V2
Group
Group 1 (Lifeline) -> Name "lifeline"
Slides number
1
COMMAND_CLASS_SENSOR_MULTILEVEL SENSOR_MULTILEVEL_REPORT. Reported temperature and humidity when the
conditions established by the user are met through the configurations 30, 31, 32, 33.
COMMAND_CLASS_THERMOSTAT_MODE.THERMOSTAT_MODE_REPORT
Transmitted when the work mode changes due to a local action or through the Network controller.
Automatic Reports
COMMAND_CLASS_THERMOSTAT_OPERATING_STATE.THERMOSTAT_OPERATING_STATE_REPORT
Transmitted when the device changes the status of the climate system management.
COMMAND_CLASS_THERMOSTAT_SETPOINT.THERMOSTAT_SETPOINT_REPORT
Transmitted when the setpoint temperature changes either by local action, by the controller of the Network or by time conditions.
COMMAND_CLASS_DEVICE_RESET_LOCALLY_NOTIFICATION
It is sent to the associated nodes when the device is removed from the Z-Wave network.
8
COMPLIANCE WITH Z-WAVE PROTOCOL
Basic Set
Basic Report
Device Type
Generic Device Type
Specific Device Type
Role Type
IU, SonS
IU, SonS
IU, SonS
IU, SonS
IU, SonS
IU, SonS
IU, SonS
IU, SonS
IU, UonS
IU, SonS
IU, SonS
IU, SonS
IU, SonS
IU, SonS
IU, SonS
IU, SonS
IU, UonS
IU: Included in an unsecured way
IU, SonS
UonS: Unsecured request when included securely
IU, UonS
SonS: Secure request when included securely
ASSOCIATION GROUPS
CC BASIC MAPPING OF VALUES
0x00 -> The device turns into mode OFF
0xFF -> Set the heat mode to AUTO
0x00 -> Indicates that the device is in mode OFF
0xFF -> Indicates that the device is in a mode other than OFF
SPECIFICATION OF THE DEVICE Z-WAVE
Thermostat - HVAC
GENERIC_TYPE_THERMOSTAT
SPECIFIC_TYPE_THERMOSTAT_GENERAL_V2
ROLE_TYPE_SLAVE_ALWAYS_ON