Maintenance

Clean the scale regularly with a towel, making sure that no water comes into the housing. The platter can be removed
and washed down, with normal household cleaning fluid.

Error Message

When the scale shows an error message, always first turn off the
scale, wait for approx. 5 seconds and turn on the scale. Refer to
the error message list, when the error message is still in the
display. Error message list:
E11
RAM error
E16
ROM error
E18
EEPROM error
E34
PLU No. too big
No PLU
PLU not found
nnnnnn
Over capacity
in weight
display
uuuuuu
Negative weight
Tiger II
Call METTLER
TOLEDO service
PLU No. 1~`100
Program PLU
Remove weight from
Platter
Re-zero the scale

Specification

Capacity:
3kg or 6kg or 15kg or 30kg
Division:
1g or 2g or 5g or 10g
Weight display:
6 digits
Unit display:
6 digits
Total price display:
6 digits
Operating temperature: -10
Storage temperature:
-25
Power supply:
12VDC~14VDC
Power consumption:
20mA
Charging current:
500mA
Plug in adapter:
I/P: 230VAC 50HZ
O/P:12VDC/800mA
Specifications are subject to change without
notice.
GB
o
o
C~+40
C
o
o
C~+50
C