Transporting and setting up the machine

4.1 Installation location

The installation location must meet the following require-
ments:
– Stable foundation with straight, even surface (for ma-
chine weight, see section 3.1).
– Keep 30 cm work area free on both sides and in front of
the machine.
– Electricity and compressed air ports easily accessible
close by.
Optimum operating pressure is 5.5 bar
(± 0.5 bar). When operating pressure is less than
5 bar, you will not achieve satisfactory crimping
results. Operating pressures greater than 6 bar
will lead to increased wear on the machine.

4.2 Transporting the machine

► Always wear work shoes with foot protection
when transporting the machine.
► Empty the waste container prior to each transport.
► Note the weight of the machine (see section 3.1). Use a
transport aid if necessary.
► To move the machine, always use the side carry han-
dles.
► To prepare the machine for shipping (e.g. in the event of
servicing), use the transport packaging.

4.3 Unpacking the delivery

► Check the delivery for completeness (for scope of deliv-
ery, see below).
► Store away the transport packaging.
► Ensure that the operating instructions are accessible to
the user at all times.

4.4 Scope of delivery

– Stripping and crimping machine with oscillating conveyor
bowl
– 1 additional vibrating conveyor bowl
– Mains connection cable (10 A, 250 V)
– Compressed air hose
– 2.5 mm Allen key (LS: 2.5 mm and 5 mm)
– Operating Instructions
2518100000/03/06.2017

4.5 Establishing connections

► Set up the machine in the intended location.
Figure 4.1 Establishing connections
► First switch on the compressed air hose on the com-
pressed air maintenance unit of the machine (1).
► Only then connect the compressed air hose with the
compressed air source.
► Check the manometer display (2). The operating pres-
sure must be between 5 and 5.5 bar.
► If necessary readjust the operating pressure. To do this,
pull the adjusting screw (3) upwards and turn it carefully:
– To increase the pressure, turn in a clockwise direction
– To reduce the pressure, turn in an anti-clockwise
direction
► Insert the power cable into the mains connection
socket (4) of the machine and connect it to the power
supply.
3
2
1
4