The barriers can be installed to the wall using the mounting plate and the pole using the mounting plate and
the "U" bracket (Pole diameter 48-50 mm).
- Remove cover via screw at base of cover.
- Loosen the unit base mounting screw and remove mounting plate by sliding it against the unit base.
WALL MOUNTING
1. Insert the cable alarm screen in the hole of the plate and fix to the wall with screws.
2. Pass the cable through the gasket in the base and anchor on the same plate. Make connections to
the terminal.
3. Following the calibration and verification of proper operation of the system, replace the IR Cover.
POLE MOUNTING
1. Drill a 8 mm hole through pole where the beam will be mounted for wiring.
2. Place U-Shape bracket at the pole.
3. Pull out the wire through the hole and through the wiring hole of the mounting plate, attached the
mounting plate to the U-Shape bracket with screw.
4. Connect the wire to the terminals
5. Checking optical alignment and correct operation
6. Replace the cover and fasten the cover lock screw tightly.
18
3. INSTALLATION
EL60RT 2PH 60m
EL120RT 2PH 120m