To obtain the message in the control panel of environmental disqualification, you must insert the jumper in
DIS ON and connect a "OPEN COLLECTOR NEGATIVE" to the output DIS OUT. This feature allows output
to the control panel of environmental disqualification, for which the barrier is in a standby state, this will avoid
annoying false alarms caused by weather conditions.
Insert jumper in DIS ON
On mother boards TX and RX there is a supplementary Tamper input useful to add a wall tamper. In case of
absence of additional Tamper, check the closing of the contact by a jumper.

8. ENVIRONMENTAL DISQUALIFICATION

9. ADDITIONAL TAMPER

Tamper input additional, in case of absence
MUST be closed by jumpers.
EL60RT 2PH 60m
EL120RT 2PH 120m
With the supplied cable connect the
output OUT DIS (open collector
negative) to bring the output in the
control panel