Control Valve; Power Failure - Honeywell KaltecSoft PW50AS Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

10. Settings
10.1 Time
Input: 24-hour mode
4.
Set the time via the
o The clock runs quicker when the
tons are held pressed
Time

10.2 Control valve

All settings at the control valve have to be entered in
the check list!
Incorrect parameter changes can lead to substantial
property damages!
In order to accept changes for the control valve set-
tings, run the programming until the end.
Proceed with the
10.2.1Capacity setting
1.
Simultaneously press the
conds
If
is displayed, press no further but-
tons (test mode manufacturer)!
Wait for approx. 10 seconds until the current time is
redisplayed!
2.
Enter the calculated set value via the
tons
3.
Press the
button once to go to the next setting
In operation or water consumption the residual capac-
ity is reduced from the set amount to zero.
Residual volume 530 litres
10.2.2Time-delayed, volume-controlled regeneration
Regeneration is triggered at the set time if the remaining ca-
pacity does not suffice for the next full day
Set to 02:00 a.m. at the factory!
Input: 24-hour mode
Time regeneration
1.
Press the
and
2.
Press the
button once to go to the next setting
MU1H-1412GE23 R0110
and
buttons
and
but-
button!
and
buttons for 5 se-
and
but-
Residual volume 0 litres
buttons to change the time
GB
10.2.3Forced regeneration
If the programmed number of days between two re-
generations has been reached, a forced regeneration
is triggered at the set time. The forced regeneration is
triggered irrespective of the residual volume.
Set to 7 days at the factory!
Input: OFF up to 99 days
Forced regeneration
1.
Press the
and
of days
2.
Press the
button once to accept all the changes
10.3 Manual Regeneration
There are two manual regeneration possibilities available
1.
Possibility
Press the button
Manual regeneration starts immediately
1.
Possibility
Briefly press the
key
Manual regeneration starts at the set time
Operating display flashes
10.3.1Change to the next regeneration phase
1.
Press the
button once to go to the next regenerati-
on phase
If the water conditioning device is in between two phases
(phase display flashes), pressing the button has no ef-
fect

11. Power Failure

11.1 Settings
The time has to be reentered after a power failure
(Chapter 10.1)
All the control valve settings remain and are restored once the
power supply has been reconnected
11.2 General Information
After the power supply has been reconnected, it is recom-
mended to start a manual regeneration (Chapter 10.3)
12. Maintenance
12.1 Block Salt Level
To be checked frequently (e.g. weekly).
1.
Remove the covering cap from the cabinet
2.
Remove the salt lid from the cabinet
3.
Check the level in the cabinet
4.
If the salt level has fallen below 10 cm, Refill block salt
(Chapter 8.2)
5.
Attach the salt lid
6.
Replace the covering cap on the cabinet
11