12.2 Maintenance
According to European and national standards, regular main-
tenance measures must be taken. Honeywell provides suita-
ble maintenance kits
Maintenance work should only be carried out be qual-
ified staff!
Device for single-family houses
interval: annually
Device for apartment blocks, public institutions
interval: every 6 months
12.3 Cleaning
Interval: every 6 months (depending on local condi-
tions)
To be carried out by an installation company
•
To be carried out by the operator
Do not use cleaning agents that contain solvents when
cleaning the plastic parts!
Detergents must not be allowed to enter the environ-
ment or the sewerage system!
14. Troubleshooting
Problem
No water supply to the device
Device does not regenerate
Nothing is displayed
Incorrect time is displayed
Tank overflows
MU1H-1412GE23 R0110
GB
Cause
Shut-off device in the bypass is not open or
only partially open
Pipework of the drinking water supply is
calcified or blocked
Flow meter is defective
Incorrect settings at the control valve
Water meter is contaminated or defective Clean and, if necessary, replace water me-
Internal electric cabling is defective
Wrong connection of connecting hoses
Control head is defective
Power supply has been interrupted
Control head is defective
Power failure occurred
Internal pipework is contaminated or leak-
ing
Float valve is defective
12
1.
Set the water conditioning device to "Bypass"
(handles to position cross)
2.
Remove the covering cap from the cabinet
3.
Remove the salt lid from the cabinet
4.
Check the inner and outer brine tube for contamination
and salt deposits
5.
Clean the inner and outer parts with water and a cloth
6.
Check the inner and outer cabinet for contamination and
salt deposits
7.
Clean the inner and outer parts with water and a cloth
8.
Attach the salt lid
9.
Replace the covering cap on the cabinet
10. Set the water conditioning device to "Service"
(handles to position straight)
13. Disposal
•
Cabinet made of high-quality plastic material
•
All components subject to pressure in glass-fibre-rein-
forced plastics
•
All components to brine in Noryl
Observe the local requirements regarding correct
waste recycling/disposal!
Remedy
Open shut off valve fully
Clean or replace the pipework
Check and, if necessary, replace the flow
meter (CS*)
Check the control valve settings
ter (CS*)
Check internal electric cabling (CS*)
Call Technical Customer Service
Connect the flexible connection lines cor-
rectly
Call Technical Customer Service
Check power suppy (mains plug, fuse)
Call Technical Customer Service
Set the time
Check pipework (CS*)
Check float valve (CS*)
www.honeywell.com