CAUTION:
1. TURN OFF GAS AND ELECTRICITY
If the cooktop is installed in the counter, 1) shut
off the gas valve to the cooktop, and 2) remove
cooktop power cord from electrical outlet or turn
breaker off at breaker box and 3) turn all control
knobs to the "OFF" position.
2. CONVERT PRESSURE REGULATOR
FROM 6" W.C. TO 10" W.C.
The gas pressure regulator supplied with the unit is
convertible from natural gas to propane (LP) gas.
To operate correctly on propane gas, the pressure
regulator must be converted as follows: (See Fig.
1.)
a) REMOVE THE HEXAGON CAP from the top of
the regulator.
b) REMOVE THE PLASTIC BUTTON IN THE CAP
AND TURN IT OVER, pressing it firmly in place so
that the letters "LP" can now be seen upright in the
stem.
c) REPLACE THE CAP and button assembly into
the top of the regulator sealing it firmly. Make
certain spring is still in place.
d) Finally, INSTALL THE FOIL CONVERSION
STICKER next to the rating plate, located on the
bottom corner of the rough-in-box.
(Note: Arrow on back part of regulator needs to
point in the direction of gas flow to the cooktop.)
3. REPLACE MAIN ORIFICES and
VENTURIS
REMOVE GRATES, BURNER CAPS, BURNER
BASES AND VENTURI NUTS. Maintop does not
require removal.
REMOVE MAIN ORIFICES.
Note: The Bosch Cooktop models contain 7mm
orifices. A method of retaining main orifices in the
socket during extraction and insertion is to apply a
piece of foam tape to the socket (see Fig.3).
Insert the socket driver with 3" minimum extension
into the jet holders to remove existing orifices, as
shown in Fig 4.
Tige
Tige
Figure 2
Burner
Cap
Igniter
Venturi
Burner
Base
Maintop
3