Fireplace Installation
in the most appropriate place for
securing and using the provided
L-bracket and the screw that was
removed attach the firebox to the
mantel. (Figure 2)
! NOTE: There are no guide
holes provided for the L-Brackets
in the mantel.
Custom Installation
1. Mark the desired location on
the floor and store the fireplace
in a safe, dry and dust free
location.
2. Frame an opening of 27.0 in.
(686 mm) wide x 23 ⅜ in. (593
mm) high x 7 ½ in. (191 mm)
deep (Figure 3).
Option #1 - The power cord can
be lead from behind the trim and
along the wall to an outlet near
the fireplace.
Option #2 - A new outlet can be
installed inside the new frame
construction. Plug the unit directly
into a 15 A, 120 V outlet.
! NOTE: A 15 Amp, 120 Volt
circuit is required. A dedicated
circuit is preferred but not
essential in all cases. A dedicated
circuit will be required if, after
installation, the circuit breaker
trips or fuse blows on a regular
basis when the heater is operating.
Figure 2
Figure 3
7 ½ in.
A
(191 mm)
Additional appliances on the same
circuit may exceed the current
rating of the circuit breaker.
3. Install the provided plastic feet
to the unit as shown in Figure 4.
CAUTION: Clearance for
air circulation beneath the
fireplace insert is provided by
feet.
C
27.0 in.
B
(686 mm)