Testing the functioning of the emergency release
Test the functioning of the emergency release after commissioning.
During this test the device has to be in the same position as during operation.
Switch off the control unit.
CAUTION
Risk of crushing when actuating the emergency release.
Ensure that no body parts can become caught between lever and device housing or carriage
when actuating the emergency release.
Wear protective gloves when actuating the emergency release.
To actuate the emergency release and lift the drive wheel, pull the lever downwards with
force until you can feel it latch in.
The drive is lifted into the basic position. The lever stays locked in the lower position
WARNING
Risk of bones being broken or crushing injuries when releasing the latched-in lever by force.
Only release the lever as described here..
Switch on the control.
Press the drive switch for three seconds.
The emergency release is cancelled. The drive wheel remains in the basic position.
Press the drive switch again.
The drive wheel is lowered in normal mode. Proceed as follows if this does not happen:
Switch off the control.
Ensure correct connection and proper functioning of the control.
Ensure that the micro-switch is in the correct position.
Repeat the function test.
Contact your sales partner if the device is not functioning properly.