Output 2:
Relay with potential free change-over
contact
switching voltage max. 250V AC / 300V DC
switching current max. 3 A
switching current for DC min. 30 mA
switching performance max. 50W for
DC and max. 2000 VA for AC
or
optocoupler with open collector and emitter
switching performance: 30V DC / 15 mA
V
at I
= 15 mA: max. 2.0V
ce sat
c
V
at I
= 5 mA: max. 0.4V
ce sat
c
Responding time of outputs:
Relay:
Optocoupler: approx. 1 ms
Data retention:
min. 10 years or 10
Transmitter voltage:
24V DC –40% / +15%, 80 mA
unstabilized for AC-versions
for option "backlit LCD"
24V DC –40% / +15% 60mA
unstabilized
Fuse protection:
recommended fuse
for DC:
for 230V AC: 0.05 AT
for 115V AC: 0.1 AT
for 48V AC: 0.2 AT
for 24V AC: 0.4 AT
Noise immunity:
EN 55011 class B and EN 50082-2
with shielded data inputs
Ambient temperature:
0 to 50°C [32 to 122°F]
Dimensions in mm [in.]:
48 [1.89]
15.5 [0.61]
panel cut-out 45 x 45 [1.77 x 1.77]
55 [2.17]
15.5 [0.61]
with front frame No. 2
8
approx. 6 ms
6
memory cycles
0.125 AT
max. 10.5 [0.41]
86.5 [3.41]
max. 9.5 [0.37]
85.5 [3.37]
panel cut-out 50 x 50 [1.97 x 1.97]
Storage temperature:
-25 to 70°C [-13 to 158°F]
Weight:
approx. 240 g [8.46 oz.]
(AC-version with relay)
Front panel rating:
IP 65
Color of housing: black
Cleaning:
The front of the unit is only to be cleaned
with a soft cloth moistened with water.
11. Contents:
– Counter
– Screw terminal plug 7 poles, 5.08 mm [0.2 in.] spacing
– Screw terminal plug 7 poles, 3.81mm [0.15 in.] spacing
– Bezel for screw mount, panel cut-out 50 x 50mm
[1.97 x 1.97 in.]
– Bezel for clip mount, panel cut-out 50 x 50 mm
[1.97 x 1.97 in.]
– Bezel for clip mount, panel cut-out 45 x 45 mm
[1.77 x 1.77 in.]
– Panel mounting clip
12. Ordering Code
E5148C24xx
60 [2.36]
Sinking
DIN 74
3 [0.12]
with front frame No. 3
4 [0.16]
21 = 90 – 260 VAC
22 = 10 – 30 VDC
max. 9.5 [0.37]
85.5 [3.37]
15.5
[0.61]
panel cut-out 50 x 50
[1.97 x 1.97]
MN05401005E
4 [0.16]