INTRODUCTION
The Macnaught 5:1 and 10:1 Ratio Oil Pumps are designed to
dispense lubricating oil, engine oil, gear oil, automatic
transmission fluid and anti-freeze/anti-boil or compatible
GENERAL INFORMATION
Please read this information carefully before use. Your safety
is important to us. Please read and follow all operating and
safety instructions listed below. Make sure all operators have
adequate access to the following instructions.
If you experience problems with this product, refer to the
troubleshooting section of this manual. If you require further
assistance please contact your local Macnaught Distributor.
IMPORTANT INFORMATION
READ THIS INFORMATION
CAREFULLY BEFORE USE
Do not exceed the maximum recommended air inlet pressure
of 1035 kPa / 150 psi / 10.3 bar. The
minimum air inlet pressure of 400 kPa / 60 psi / 4 bar and we
recommend that you operate the unit at 690 kPa / 100 psi /
6.9 bar.
Do not hit the unit if it fails to operate.
Use suitable thread sealant ( e.g. Teflon tape ) on all screwed
fittings, but do not over tighten to avoid component damage.
Never allow any part of the human body to come in front of,
or in direct contact with a material outlet.
Never exceed the pressure rating of any component installed
in the system.
Check all hoses for signs of wear, leaks or loose fittings. Tighten
all fluid connections regularly and replace weak or damaged hose.
Your personal safety and well being are at stake.
Before attempting any maintenance or repairs of this product,
disconnect the air supply and release the oil line pressure by
squeezing the hand piece / gun trigger.
ASSEMBLY
Measure the depth of the drum/tank and attach the appropriate
length of threaded pipe to the inlet of the pumps (R500S and
R1000S). There are a range of telescopic suction tubes available
from Macnaught.
Remove the bung adapter assembly from the pump and screw it
into the drum/tank opening. Carefully lower the pump through the
bung adapter and tighten the ring nut firmly.
Connect the appropriate hose and / or dispensing equipment to
your pump outlet.
Before connecting the air supply, the user should add a 'stop'
valve compressed air cock.
Note: The air cock must be a ¼ turn type ( allowing quick
closure ) and should be located close to the body of the
pump and be easily recognized.
TG040 Issue 15 © 2019
R500 / R1000
AIR OPERATED OIL PUMPS
INSTRUCTION MANUAL
pumps require a
(R1000S)
Adjust the on/off air valve to regulate the flow. Close the delivery
outlet/nozzle to stop flow.
Note: To protect the pump an in-line oiler must be used. It is
also recommended that a micro-fine (5 micron) air filter is
fitted to the air inlet of the pump to ensure maximum
efficiency of the pump.
CAUTION
Do not run the pump dry. Remember to switch off the air supply
to the pump if not using for an extended period of time. (eg. At the
end of each working day)
OPERATION
1) Ensure the drum or tank is "vented".
2) Partially open the on/off air valve. The pump will prime
automatically.
3) Open the delivery outlet/nozzle. The pump will automatically
start.
4) Adjust on/off air valve to regulate the flow. Close delivery outlet/
nozzle to stop flow.
CAUTION
Before carrying out any maintenance disconnect the air
supply and release the fluid pressure in the system.
(R500S)
Page 1 of 12

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Macnaught T1000S-01 R1000T-01

  • Página 1 R500T-01 INSTRUCTION MANUAL R500T-02 INTRODUCTION The Macnaught 5:1 and 10:1 Ratio Oil Pumps are designed to dispense lubricating oil, engine oil, gear oil, automatic transmission fluid and anti-freeze/anti-boil or compatible GENERAL INFORMATION Please read this information carefully before use. Your safety is important to us.
  • Página 2: Troubleshooting Guide

    MAINTENANCE COMPLETE PUMP DISASSEMBLY 1) Disconnect air supply and release oil line pressure. Inspect your oil pump and associated hoses weekly for any signs of damage. Replace any damaged or worn components. 2) Withdraw pump from the oil drum/tank. (Use a clean bench to carry out maintenance).
  • Página 3 Français POMPES À HUILE PNEUMATIQUES NOTICE D'UTILISATION Les pompes à huile à rapport 5:1 et 10:1 de Macnaught sont Régler la vanne d'arrivée d'air pour réguler le débit. Fermer conçues pour distribuer de l'huile lubrifiante, de l'huil moteur, l'orifice ou la buse de refoulement pour interrompre le débit.
  • Página 4: Démontage Complet De La Pompe

    6) Soulever l'adaptateur supérieur (9) afin de dégager les orifices 5) Pour le démontage du moteur pneumatique, voir le paragraphe d'échappement situés sur la tige de piston (41). précédent intitulé « Démontage de la pompe ». Pour procéder à l'entretien du moteur pneumatique et de la garniture de tige de 7) Pour retenir la tige de piston (41), insérer une broche en acier piston, suivre les points 2 à...
  • Página 5 Deutsch R500 / R1000 DRUCKLUFTBETRIEBENE ÖLPUMPEN BEDIENUNGSANLEITUNG Die Macnaught-Ölpumpen mit dem Druckverhältnis 5:1 oder Hinweis: Zum Schutz der Pumpe muss ein Leitungsöler 10:1 sind zum Schmieren mit Motorenöl, Schmieröl, verwendet werden. Darüber hinaus wird zur optimalen Getriebeöl, Automatikgetriebeöl und Frost- bzw.
  • Página 6 8) Die drei Luftventilschrauben (2), Unterlegscheiben (3) und 7) Den Splint (35), das Ventilgehäuse (23) und die Distanzstücke (4) vom Luftventil entfernen und dann die Kolbenanordnung von der Kolbenstange (41) losschrauben und Luftventilkappe (49) abnehmen. 8) Das Ventilgehäuse (23) und die Kolbenanordnung (26) 9) Den Kolbenstangenbolzen (48) losschrauben und das Luftventil auseinanderbauen.
  • Página 7: Bombas De Aceite

    R500 / R1000 BOMBAS DE ACEITE MANUAL DE INSTRUCCIONES Las bombas de aceite Macnaught de relación 5:1 y 10:1 están Ajuste la válvula de aire de apertura/cierre para regular el flujo. diseñadas para suministrar aceite de lubricación, aceite de Cierre la salida/boquilla de suministro para cerrar el flujo.
  • Página 8: Montaje De La Bomba

    8) Extraiga los tres tornillos (2), arandelas (3) y separadores (4) 8) Desmonte el alojamiento de la válvula (23) y el conjunto del del conjunto de la válvula de aire y luego extraiga la tapa de la pistón (26). válvula de aire (49). 9) Extraiga la biela del pistón (41) del adaptador inferior (15).
  • Página 9 R500 PARTS DIAGRAM R500 PARTS LIST Order for replacem ent Item No off Part or Set Kit ref Description R500-2K (A) Major service kit R500-3K (B) Seal kit TG001s (incl item 50, BS045, BS046) Air motor cap A & B Air valve screw A &...
  • Página 10 R1000 PARTS DIAGRAM R1000 PARTS LIST Order for replacement Item No off Part or set Kit ref Description R1000-1K (A) Major service kit R1000-2K (B) Seal kit TG001s (incl item 50, BS045, BS046) Air motor cap A & B Air valve screw A &...
  • Página 11: Product Specifications

    Product Specifications Specifications R500 R1000 Maximum Air Pressure 1035 kPa / 150 psi / 10.3 bar 1035 kPa / 150 psi / 10.3 bar Minimum Air Pressure 400kPa / 60 psi / 4 bar 400kPa / 60 psi / 4 bar Typical Air Consumption 18cfm @ 690kPa / 100 psi / 6.9 bar 18cfm @ 690kPa / 100 psi / 6.9 bar...
  • Página 12 This product should be disposed of according to all applicable local and national government environment regulations and guidelines. For Warranty Terms and Conditions see macnaught.com.au For a list of Australian Service Centres see macnaught.com.au TG040 Issue 15 © 2019 Page 12 of 12...