Reset To Factory Default Settings; Further Information - Axis M11 Serie Guia De Instalacion

Ocultar thumbs Ver también para M11 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 85

Reset to Factory Default Settings

Important
Reset to factory default should be used with caution. A reset to
factory default will reset all settings, including the IP address,
to the factory default values.
Note
The installation and management software tools are available
from the support pages on www.axis.com/techsup
To reset the product to the factory default settings:
1.
Disconnect power from the product.
2.
Press and hold the control button and reconnect power. See
Hardware Overview on page 10.
3.
Keep the control button pressed for 15–30 seconds until the
status LED indicator flashes amber.
4.
Release the control button. The process is complete when the
status LED indicator turns green. The product has been reset to
the factory default settings. If no DHCP server is available on
the network, the default IP address is
5.
Using the installation and management software tools, assign
an IP address, set the password, and access the video stream.
It is also possible to reset parameters to factory default via the web
interface. Go to Setup > System Options > Maintenance.

Further Information

The User Manual is available at www.axis.com
Visit www.axis.com/techsup to check if there is updated firmware available
for your network product. To see the currently installed firmware version,
go to Setup > About.
Available from A1 Security Cameras
www.a1securitycameras.com email: sales@a1securitycameras.com
AXIS M11 Network Camera Series
21
192.168.0.90

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

M1124M1125

Tabla de contenido