MAKING MINOR
ADJUSTMENTS BETWEEN
DOORS
Remember, a leveled refrigerator is necessary
for getting the doors perfectly even. If you need
help, review the previous section on leveling the
refrigerator.
The left door is fixed. To make minor
adjustments between doors, adjust only
the right door.
1. Pull out the freezer drawer ( 1 ) to reveal the
lower hinge ( 2 ).
2. Insert a philips screwdriver (+) ( 3 ) into the
shaft ( 4 ) of the lower hinge.
3. Adjust the height by turning a philips screwdriver
(+) ( 3 ) clockwise (
(
).
UP
When you turn a philips screwdriver (+)
counterclockwise (
move up.
1
DA68-02603A-10.indb 10
Adjustment
part
Fixed part
) or counterclockwise
DOWN
), the door will
2
4
3
3
English - 10
INSTALLING THE WATER
DISPENSER LINE
A water dispenser with a filter is one of the helpful
features on your new refrigerator. To help promote
better health, the water filter removes unwanted
particles from your water. However, it does not
sterilize or destroy microorganisms. You may need
to purchase a water purifying system to do that.
The water line also connects to the ice maker.
For the ice maker to operate properly, water
pressure of 20~125 psi (138~862 kPa) is required.
If the refrigerator is installed in an area with low
water pressure (below 20 psi), you can install
a booster pump to compensate for the low
pressure.
After you have connected the water line, make
sure the water storage tank inside the refrigerator
is properly filled. To do this, press the water
dispenser lever until the water runs from the water
outlet.
Water line installation kits are available at
extra cost from your dealer.
We recommend using a water line
installation kit that contains copper tubing
and ¼" compression nut.

Connecting to the water supply line

1. First, shut off the main water supply.
2. Locate the nearest cold water drinking line and
install the pipe clamp and shut off valve.
Cold water line
Pipe clamp
Shut off valve
3. Connect the water line installation kit to the
shut off valve.
2015. 11. 5.