Parameters (mfx)

No CVs are required for the settings on the decoder when using mfx. The required definitions are briefly explained here:

Root Block

This block cannot be edited. Only information about the decoder, the hardware, and the software are shown here.

Configuration Block

Designation
Flags
Switching Prot.
Addressing
Switching Rev.
Turnout Lantern
Address
Number of Sub-Addresses
Automatic Circuits
Type of Automatic Circuit
Mode Preset

Output

Mode
Duration
Dimmer
Period
Switching Group
Read
Meaning
only
Cannot be changed
x
Cannot be changed
Cannot be changed
Cannot be changed
Switching address, address of the first turnout
x
Indicates how many addresses are occupied
x
Indicates which automatic circuits are set up
Selection of the automatic circuits for the outputs 1&2 and 3&4
See DCC, CV 79
See DCC, "Configuration of the Outputs", "Switching Function" or table on Page 22
Continuous activation of the output, switches the output continuously on
Controls the brightness of lights connected to the output, 0 = off, 255 = not dimmed
Indicates how fast the switching impulse is supposed to be repeated (Example: blinking light)
Not occupied in this item