CAPACITY CURVES
Tested at room temperature, using water. Flooded pump with 3.5 inches
(80 mm), positive suction head.
INSTALLATION

INSTALLATION RECOMMENDATIONS

• Remove the pump from its package and install it on the chosen location.
• Try to minimize the suction head. Install the pump as close as possible to
the fluid being pumped.
• Remember to have enough space around the pump to perform
maintenance tasks.
• Keep in mind to connect the inlet and outlet of the pump correctly.
• In case of diaphragm pump failure, the air exhaust will expel the product
being pumped.
• When the pump is installed in a place where a spill of fluid can cause an
environmental impact, the exhaust should be directed to a place.where
this spill could be contained.
• When installing the pump in its place, use brackets to secure its base.
• Fasten all bolts with the torques contained in this manual.
FLOODED
4
SB 1147
Rev A 07/2017
Balcrank Corporation • Weaverville, N.C. 28787 • Phone (800) 747-5300 • Fax (800) 763-0840
114
8
7
100
6
87
72,5
5
58
4
3
43,5
2
29
1
14,5
0
0
U.S. glp
0
6.6
13.2
0
25
50
lpm
8
114
100
7
87
6
72,5
5
4
58
3
43,5
29
2
14,5
1
0
0
U.S. glp
0
6.6
13.2
0
25
50
SUBMERGED
lpm
19.8
26.4
33
39.6
75
100
125
150
FLOW
Air consumption
Pump flow
CF pumps are very easily configured and easy to install.
FLOODED:
The pumping system was designed with positive pressure at the inlet. This is
the best possible installation when you need to evacuate the liquid from the
drum or tank, or when working with viscous fluids.
Not recommended for hazardous fluids.
SELF-PRIMING:
Pump is designed to generate vacuum. It is possible to evacuate all the air
from a hose or pipe without damaging the pump. Maximum suction height
is 19.69 ft (6 m), with the suction hose empty and up to 26.25 ft (8 m) with
the hose primed. (See page 1 for corresponds suction lift).
SUBMERGED:
All pumps can be immersed in fluids. It is important to verify that all
components that are in contact with the fluid are chemically compatible. In this
case, air exhaust and fluid must be carried by hoses (optional air connection).
19.8
26.4
33
39.6
75
100
125
150
CAUDAL
49.42
1300
42.36
1100
35.3
900
28.24
700
500
21.18
14.12
300
7.06
100
0
0
46.2
53,2
175
200
49.42
1300
42.36
1100
35.3
900
28.24
700
21.18
500
14.12
300
100
7.06
0
0
46.2
53,2
175
200
NOTE: Use a pressure regulator with
built-in filter inlet.
NOTE: The compressed air supply
must be between 43.5 psi (3 bar)
and 115 psi (8 bar).