Requirements for electric animal fences
In accordance with Annex BB Section BB.1 of IEC
60335-2-76
Electric animal fences and their ancillary equipment shall be
installed, operated and maintained in a manner that
minimises danger to persons, animals or their surroundings.
Electric animal fence constructions that are likely to lead to
the entanglement of animals or persons shall be avoided.
WARNING!
especially with the head, neck or torso. Do not climb
over, through or under a multi-wire electric fence. Use a
gate or a specially designed crossing point.
An electric animal fence shall not be supplied from two
separate energizers or from independent fence circuits of
the same energizer.
For any two separate electric animal fences, each supplied
from a separate energizer independently timed, the distance
between the wires of the two electric animal fences shall be
at least 2.5 m (8'). If this gap is to be closed, this shall be
6
Avoid contacting electric fence wires