TO CONVERT APPLIANCE FOR USE WITH NATURAL GAS
Propane Gas (LP) To Natural Gas
Conversion Instructions
If this appliance has been converted for use with LP Gas,
each of the following modifications must be performed to
convert the unit back to Natural Gas.
WARNING
Natural Gas conversion is to be performed by a
Jenn-Air Authorized Service Contractor (or
other qualified agency) in accordance with the
manufacturer's instructions and all codes and
requirements
of
jurisdiction. Failure to follow instructions could
result in serious injury or property damage. The
qualified agency performing this work assumes
responsibility for this conversion.
WARNING
ELECTRICAL POWER AND GAS MUST BE
TURNED OFF PRIOR TO CONVERSION
BURNER
Left Rear (LR)
Left Front (LF)
Center Rear (CR)
Center Front (CF)
Right Rear (RR)
Right Front (RF)
the
authority
having
BTU/hr
8,000
8,000
10,000
10,000
10,000
10,000
Model - JGD8348CDP
Manifold - Natural Gas pressure required - 5² W.C.
Incoming Natural Gas pressure required to appliance
pressure regulator - 6² - 7² W.C.
Natural Gas input specified - 56,000 BTU/hr.
A. Replace all orifice hoods - Perform steps 1 through 4 on
page 7. Locate the (6) six Natural Gas hoods (with small
numbers stamped on their sides saved from the original
Natural Gas unit). Page 5 Illustration "E". The two
hoods with .0520 (#55 orifice) stamped on them are for
the left front and left rear burners. The four hoods with
the .0595 (#53 orifice) stamped on them are for the two
right burners.
To make these conversion adjustments follow the
instructions and illustrations ("A" through "E") pages
5-7.
B. Invert cap in appliance pressure regulator (see
Illustration "D", page 6). With the appliance installed,
the appliance pressure regulator is located on the right
underside of the appliance at the inlet to the gas
manifold. Identify the type of appliance pressure
regulator on the unit and follow the instructions in the
appropriate illustration.
C. Adjust low flame setting for each burner. Follow the
instructions for burner low flame adjustment on page 7
to increase the simmer flame size.
JGD8348CDP
INCHES
ORIFICE
DIAMETER
#55
.0520
#55
.0520
#53
.0595
#53
.0595
#53
.0595
#53
.0595
9
COLOR
Green
Green
Brass
Brass
Brass
Brass