FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
The 50E47-843 is a universal replacement Hot Surface Ignition
(HSI) control designed for maximum compatibility with existing
systems. It features:
A card port and six program keys to select the
Trial for Ignition Time, Retries, Pre-purge and
Igniter Warm Up timings.
Sense (sensing through ignitor) or Indirect Sense
(using a Flame Sensor).
troubleshooting.
GENERAL PRECAUTION
!
Application of this type of control may cause flame
rollout on initial startup and could cause personal
injury and/or property damage.
Check product specification and cross reference before
replacing existing module. Do not use if existing module
is not listed. Use of a program key other than listed can
result in appliance malfunction.
If in doubt about whether your wiring is millivolt, line, or low volt-
contractor or licensed electrician.
Do not exceed the specification ratings.
and ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.
CONTENTS
Description ................................................................... 1
Precautions .................................................................. 1
Specifications ............................................................... 2
Installation .................................................................... 2
Mounting & Wiring
Operation & Troubleshooting ......................................... 4
Universal Hot Surface Ignition Control
INSTALLATION INSTRUCTIONS
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dan-
gerous operation.
This control is not intended for use in locations where
it may come in contact with water. Suitable protection
must be provided to shield the control from exposure
to water (dripping, spraying, rain, etc.).
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
www.white-rodgers.com
www.emersonclimate.com
50E47-843
DESCRIPTION
PRECAUTIONS
CAUTION
CAUTION
!
!
WARNING
!
PART NO. 37-6426G
Replaces 37-6426F
1424

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Emerson White-Rodgers 50E47-843

  • Página 1 50E47-843 Universal Hot Surface Ignition Control INSTALLATION INSTRUCTIONS FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION The 50E47-843 is a universal replacement Hot Surface Ignition (HSI) control designed for maximum compatibility with existing systems.
  • Página 2 SPECIFICATIONS ELECTRICAL RATINGS: Program Key Timing Specifications Quick Reference Input Voltage: Timing and Retry Current: 0.2 amp Interpurge Relay Contact Ratings: Program Trial for Ignitor Key (Color) Ignition Retries Prepurge (Warmup) 4 Sec. 30 Sec. 45 Sec. resistive B (red) 4 Sec.
  • Página 3 INSTALLATION JUMPER JUMPER (clip) FLAME PROBE BURNER BURNER GROUND GROUND BLUE SURFACE SURFACE IGNITER ADAPTER IGNITER VALVE VALVE FLAME PROBE LIMIT LIMIT CONTROLLER CONTROLLER (HOT) (HOT) TRANSFORMER TRANSFORMER THERMOSTAT OR THERMOSTAT OR ALTERNATE ALTERNATE CONTROLLER CONTROLLER LIMIT LIMIT Fig. 1 – Typical hookup for White-Rodgers replacement Fig.
  • Página 4 INSTALLATION INSTALL PROGRAM KEY Specifications section of this installation manual. Choose the The control replaces all listed models with the following features: the slot on the left side of the module (see figure 4 on page 3). If the module you are replacing is not listed in the Cross Reference, contact the manufacturer of the appliance for a recommended replacement or retrofit.
  • Página 5 TROUBLESHOOTING Call for heat, Thermostat contacts close Chec w Voltage to module (TH-TR). If no voltage: Does Yello approximately 2 seconds? Chec (Module Self Chec Chec ent pressure switch (if used). Measure voltage between ter TH. If voltage is approximately 145 V polarity is reversed;...
  • Página 6 White-Rodgers is a business of Emerson Electric Co. The Emerson logo is a www.white-rodgers.com www.emersonclimate.com of Emerson Electric Co.
  • Página 7: Descripción

    50E47-843 Control de encendido de superficie caliente universal INSTRUCCIONES DE INSTALACIÓN EL NO LEER Y SEGUIR CON CUIDADO TODAS LAS INSTRUCCIONES ANTES DE INSTALAR O UTILIZAR ESTE CONTROL, PODRÍA CAUSAR LESIONES PERSONALES Y/O DAÑOS MATERIALES. DESCRIPCIÓN El 50E47-843 es un control de encendido de superficie caliente de repuesto diseñado para ofrecer la máxima compatibilidad con los sistemas existentes.
  • Página 8: Especificaciones

    ESPECIFICACIONES CARACTERÍSTICAS ELÉCTRICAS: Especificaciones de tiempos de las teclas de programa Referencia rápida Voltaje de entrada: Tiempos y reintentos Corriente: 0.2 amp TECLA DE PRUEBA CALENTAR Características de contacto de los relés: PROGRAMA PRE- DISPOSITIVO (COLOR) ENCENDIDO INTENTOS PURGADO ENCENDIDO resistivo Requisitos de corriente de llama: 2 μA CC*...
  • Página 9: Instalación

    INSTALACIÓN PUENTE PUENTE (corte) SONDA DE LLAMA TIERRA TIERRA AZUL QUEMADOR QUEMADOR ROJO DISPOSITIVO DE DISPOSITIVO DE ENCENDIDO DE ENCENDIDO DE ADAPTADOR VÁLVULA SUPERFICIE CALIENTE SUPERFICIE CALIENTE VÁLVULA DE GAS DE GAS SONDA DE LLAMA CONTROLADOR CONTROLADOR DE LÍMITE DE LÍMITE (VIVO) (VIVO) TRANSFORMADOR...
  • Página 10: Funcionamiento

    INSTALACIÓN INSTALE LA TECLA DE PROGRAMA usando la directa a través del dispositivo de encendido reacondicionamiento recomendado. el módulo. FUNCIONAMIENTO INSTALACIÓN TÍPICA DE LA CALDERA calor. Durante el período de prueba de encendido, el dispositivo de la habitación. El termostato aplica alimentación al control. Después...
  • Página 11: Solución De Problemas

    SOLUCIÓN DE PROBLEMAS Para el funcionamiento adecuado del control, éste debe estar encuentre en los componentes externos o en las conexiones (vea el de los cables del dispositivo de encendido deben estar enchufados. Tres verificaciones visuales El dispositivo de encendido se calienta y se ilumina de color rojo a conectarla.
  • Página 12 Si no hay voltaje, cambie el módulo. cambie la válvula. sí superiores a los 1000 °F pueden conectar a tierra el detector de llama. Sí Funcionamiento normal de Emerson Electric Co. www.white-rodgers.com marca comercial y una marca de www.emersonclimate.com servicio de Emerson Electric Co.