Automatic zero adjustment
•
Over range indicator (except 15 A function). Displays "OL" on
LCD
•
Low battery indicator. Displays battery symbol
•
Automatic power shut off (after 10 idle minutes)
•
Pollution Degree 2
•
Measuring circuit category II
•
Operating environment:
Temperature - 32° to 104° F. (0° C to 40° C)
Humidity - Less than 80% relative humidity (non-condensing)
Altitude - up to 6562 ft (2000 meters)
•
Storage environment:
Temperature - 4° to 140° F (- 20° to 60° C)
Humidity - Less than 90% relative humidity (non-condensing)
•
Power Supply: Two 1.5V AA batteries
•
Fuse: 0.500A/250V 5X20 mm (Radio Shac
series; #270-1047) fuse
•
Dimensions:
Height - 6.81 in. (173 mm)
Width - 6.57 in. (167 mm) (includes test lead clips)
Depth - 1.69 in. (43 mm)
•
Weight (including batteries): approximately 9.1 oz (260 g)
ELECTRICAL SPECIFICATIONS
DC VOLTS
Range
Resolution Accuracy
400mV
100µV
4V
1mV
40V
10mV
400V
1V
600V
Input impedance: 10MΩ for all ranges.
250V DC RMS
±(0.8% of
reading
+ 5 digits)
600V DC/AC RMS
±(0.8% of
reading
+ 5 digits)
k, GMA/270
Overload Protection
on LCD
4