new Construction – attaching to joist
A11
5/8
1/2
position the correct depth mark at the bottom edge of the joist
based on the thickness of your sheetrock.
A13
pull wires through the strain relief.
A14
Fan Motor
F
Light
*option Fan & Main Light Together
E
Black
2 pin
White
White
3 pin
Black Light
*option
Connect wires as shown.
43041-01 01/31/2008
A12
screw pre-loaded screws into joist or framing.
Ground
Green
A
Bare Copper
Black Main switch 1 (aC in)
White
Black
switch 2 (aC in)
6