6.7 SET PULSE REPETITION [7]
If one or both of the relays are set to pulse mode,
additional pulses can be given by pressing [#]
without the need to re-enter the PIN code. This menu
allows setting the duration of this pulse repetition
timeframe.
EN
• Access programming mode (see 6. 1 )
• Press [7] and confirm with [#]
• [7] and [#] are both lit
• Enter the timeframe within which pulse repetion is
allowed (between 1 and 99 seconds), and press
[#] (0s will disable pulse repetition)
• If a valid value is entered all lights will light up, you
will return to the main menu
In case of an invalid value, all lights will flash
three times. Menu [7] remains activated.
By default the value is set to 'no pulse repetition'
6.8 KEYPAD HEATING [8]
• Access programming mode (see 6. 1 )
• Press [8] and confirm with [#]
• [8] and [#] are both lit
• Select the mode for the keypad heating:
[1] Full power heating (default): The keypad
heating can consume up to 12W of power
[2] Half power heating: The power consumed for
keypad heating is limited to a maximum of 6W.
[3] No heating: The keypad heating is disabled.
• Press [1], [2] or [3] and confirm with [#]. When
all LEDs flash, your choice has been saved.
• You are back in the main menu of the
programming mode
In case of an invalid value, all lights will flash three
times. Start over. Menu [8] remains activated.
6.9 FACTORY RESET UPON LOSS
OF MASTER PIN
Perform a factory reset without a Master PIN:
• Switch the power supply off and on, enter the
default Master PIN '12345' and confirm with [#]
within 20 seconds
• The factory reset is complete
• In case of a factory reset as described above, the
Master PIN is reset to '12345'
12
7.
FUNCTIONING OF
SLIMSTONE-2
7.1 ENTER A CORRECT CODE
• Enter a personal code (min. 4 - max. 8 digits)
• Press [#] to confirm the code
• In case the code is only valid for 1 relay, the relay
will be activated immediately
• In case the code is valid for both relay 1 and 2,
buttons [1] and [2] will flash. Press [1] and/or [2]
to activate relay 1 and/or relay 2.
• The corresponding button lights up, and a light
sequence runs from the bottom to the top during
the time the relay is energised (default time is 8
seconds)
• If the sequence light stops, the relay is no longer
energised. The SlimStone-2 is ready for a new
code.
7.2 ENTER A WRONG CODE
• Enter a wrong code
• Press [#] to confirm the code
• All lights flash for 2 seconds, indicating a wrong
code has been entered
• If 5 or more wrong codes are entered
consecutively, you won't be able to use the
SlimStone-2 for a certain period due to safety
reasons. The time out period is specified as
follows :
[number of failed attempts]
2
seconds.
For example : 6 failed attempts result in a time out
period of 64 seconds (2
The time out period is reset when a correct
code is entered, or if no new code was entered
during 2 hours.
seconds)
6