AUTO SHUT-OFF FEATURE
The scale will automatically shut off to conserve the batteries if operating on
battery power. The auto-shut off feature can be disabled to allow the scale to
operate continuously or set from 2 minutes to 5 minutes.
1. While the scale is off, press and hold the "ON/OFF" button.
2. While continuing to hold the "ON/OFF" button, press the "COUNT" button 3 times.
3. Release the buttons. The display shows "SEt", then "P-1.00", then "AOFF".
4. Press "ZERO/
"120" for 120 second auto shut-off).
5. Press "UNIT" to cycle through the options: "120", "180", "240", "300", or "OFF"
(the scale will remain on until "ON/OFF" is manually pressed).
6. Press "ZERO/
7. Press "UNIT" until "End" displays, then press "ZERO/
8. Set up is complete. The scale returns to weighing mode.
Note: If the scale is operating on adapter power, it will remain on until the
"ON/OFF" button is manually pressed.