PRECAUTION:
1. Communication function is only supported on some models. Check the model no. and its
specification before using communication function.
2. Do not insert the plug of communication cable into torque wrench that does not support
communication function.
CONNECTING COMMUNICATION CABLE
Turn off power and then connect the accessory cable between the COM port of PC and torque
wrench.
UPLOADING RECORD DATA
1. Make sure the connection between PC and wrench is normal.
2. Change the wrench operation mode to "Send". (Please refer to "Peak Hold Mode Recorded
Value Review" section)
3. Use PC to start the uploader program.
4. In uploader program, first select the correct COM port No.
5. Next, select the file path to save the uploaded data.
6. Finally, press "upload" button to transmit the torque records to PC.
7. The uploaded data is then shown on the column and saved in the *.csv file. Use Microsoft
Excel to view *.csv file.
CAUTION:
Refer to the uploader program user guide for the detail operations.