NOT CD050107.qxd
7/10/05
DEFROST FUNCTION
If the indicator (V) is lit, the dehumidifier is in defrost mode. The compressor stops and the AIR CLEAN indicator (S) remains lit.
The compressor starts again 8 minutes after the start of the defrost mode.
CONTINUOUS DRAINAGE
Use a PVC pipe, 14 mm in diameter.
- Remove the tank from the appliance.
- Unblock the drainage opening (L) provided at the rear of the appliance with a pointed object.
- Insert the pipe in the drainage opening and place the other end of the drainage pipe in a suitable outflow.
- Connect the pipe to the drainage outlet and tighten well.
- Ensure that the slope between the 2 ends of the pipe allows water to flow away normally.
- Finally, replace the tank (the main indicator comes on and all others go out).
EMPTYING THE TANK
When the tank is full:
• The appliance stops and the red, FULL indicator (U) lights.
• Pull the tank carefully out of the appliance, lift it by the handle (F) and empty out the water.
• Once it is empty, replace the tank in the appliance.
TRANSPORT
• The appliance is easy to move, thanks to its rollers.
• Note: Your appliance includes a refrigeration compressor; laying the appliance on its side can cause a malfunction.
CARE
• It is imperative that you turn off your appliance using the button
• It can be cleaned with a damp cloth.
• Important: Never use abrasive cleaners, these will damage the surfaces.
• Your appliance is fitted with a removable, cleanable filter, which must be cleaned regularly.
- Remove the filter by sliding it outwards and wash it with tap water.
- Always take care to dry the filter before replacing it.
• Never use the appliance without its filter.
STORAGE
When the appliance is not in use, it can be stored in a dry place. Take care to empty the water tank.
TECHNICAL CHARACTERISTICS
Characteristics
Voltage and frequency
Power (W)
Humidity absorption capacity (l/day)
Weight (kg)
Ambient temperature (°C)
Refrigerant / weight (r/g)
Tank capacity (l)
Dimensions (mm)
Noise level (dB)
IN THE EVENT OF PROBLEMS
- Never dismantle your appliance. An incorrectly repaired appliance can be a danger to the user.
- Before contacting an approved Service Centre in our network, ensure that the appliance is in a normal operating position and that the air inlet and outlet
grills are completely unobstructed.
Type of problem
The appliance does not work when switched on
The dehumidification capacity is too low
The desired level of comfort is not reached after
the appliance has been operating for a long time
The appliance is too noisy
The appliance stops
ENVIRONMENT PROTECTION FIRST !
- Your appliance contains valuable materials which can be recovered or recycled.
- Leave it at a local civic waste collection point.
16:54
Page 8
and disconnect it before any cleaning operation.
DH 3010
220V-240V / 50Hz
225 W
14 l/day (32°C RF 80%)
10.5 kg
5°C – 35°C
R134a / 140g
L372*H517*T245
Points to check
Water tank full.
Positioning of the tank.
Connection of the appliance.
That the filter is clean.
The temperature is too low.
Obstruction of the air inlet and outlet grills.
Doors and windows are closed.
That the filter is clean.
Source of steam in the room.
Size of room too large.
The appliance is placed on a flat and stable surface?
Water tank full or not in place.
Temperature too high.
Bad humidity setting.
DH 3020
220V-240V / 50Hz
290W
20 l/day (32°C RF 80%)
11.2 kg
5°C – 35°C
R134a / 220g
5.4 l
42 dB
If you have any problems or queries please call our
Customer Relations Team for expert help and advice:
HELPLINE:
0845 602 1454 - UK
(01) 4751947 - Ireland
Or consult our web site: www.rowenta.co.uk
(if this is a Rowenta product).
GB