How to proceed:
E
• Fit the rubber foot (6) onto the base of the Bitron Gravity.
• Release the DN 110 quick-release coupling (3) by loosening the hexagon screws.
• Push the DN 110 quick-release coupling onto the bottom socket of the unit until the socket makes light contact with
the centre rubber lip (21).
• Tighten the hose clip on the unit side.
• Fit the DN 110 pipe collar (4) with hose clip onto the top socket such that the socket protrudes slightly out of the pipe
collar.
F
• Remove the container cover.
• Open the locking mechanisms (22) and lift out the strainer baskets.
G
• Place the Bitron Gravity into the container and connect it to the DN 110 outlet with the DN 110 pipe collar.
• Tighten the hose clip.
• Install the AquaMax Gravity Eco in the container (→ Installing the AquaMax Gravity Eco pump in the container).
Installing the AquaMax Gravity Eco pump in the container
A maximum of two AquaMax Gravity Eco pumps can be installed in the container of an Individual Module. For this
purpose, each pump must be equipped with a rubber foot and a vibration damper.
How to proceed:
H
• Fit the vibration damper (7) onto the base of the pump.
• Clip the rubber foot (8) onto the pump.
• Fit the 2"/DN 110 connection adapter (included in the delivery scope of the AquaMax Gravity Eco pump) to the
pressure socket of the pump.
I
• Position the pump with the connection adaptor at the bottom in the container.
• Turn the pump into the end position and, at the same time, insert the connection adaptor into the DN 110 quick-
release coupling until it makes contact with the centre rubber lip (21).
• Reinsert the removed strainer baskets and close the locking mechanisms (22).
• Use the cable clips (24, included in the delivery scope of the Individual Module) to fasten the connection cables to
the edge of the container and route the cables out through the cable slot.
• Fit the container cover.
Start-up
Attention! Ultra-violet radiation.
Possible consequences: Eye or skin injury from burns.
Protective measures:
• Never operate the UVC lamp outside its housing.
• Never operate the UVC lamp in a housing that is defective.
Note!
• First open the slide valve (if applicable), then switch on the pump and subsequently the UVC unit. Check all
connections for leaks.
• If using filter starter, medicines or pond water treatments, do not operate the UVC unit for at least 36 hours.
• Do not operate the unit without water flowing through it.
• The UVC unit switches on automatically when the power connection is established.
Switching on: Connect power plug to the socket. The unit switches on immediately when the power connection is
established.
Switching off: Disconnect the power plug.
D
An inspection window (24) is provided for checking whether or not the UVC lamp is lit (blue light).